A New Method to Assess Ductility of CFT Box Columns with Binding Bars under Axial Compression

Abstract:

Article Preview

A new method based on material properties instead of experimental data was proposed to assess the ductility of concrete-filled steel box columns with binding bars and those without binding bars. Comparison between ductility coefficients based on experimental data and the calculated values by the proposed method shows good agreement.

Info:

Periodical:

Advanced Materials Research (Volumes 446-449)

Edited by:

Xiuli Du, Jianjun Zheng, Weiming Yan, Yue Li and Jianwei Zhang

Pages:

78-81

Citation:

Y. L. Long and J. Cai, "A New Method to Assess Ductility of CFT Box Columns with Binding Bars under Axial Compression", Advanced Materials Research, Vols. 446-449, pp. 78-81, 2012

Online since:

January 2012

Export:

Price:

$38.00

[1] Furlong RW: J Struct. Div., ASCE, Vol. 93(5) (1967), pp.113-124.

[2] Knowles RB and Park R: J Struct. Div., ASCE, Vol. 95(12) (1969), pp.2565-2587.

[3] Schneider S. P: J Struct. Eng., ASCE, Vol. 124(10) (1998), pp.1125-1138.

[4] Uy B: Journal of Constructional Steel Research, Vol. 57 (2001), pp.114-134.

[5] Han L-H: Journal of Constructional Steel Research, Vol. 58 (2002), pp.353-372.

[6] Liu Dalin, Gho W-M and Yuan Jie: Journal of Constructional Steel Research, Vol. 59 (2003), pp.1499-1515.

DOI: https://doi.org/10.1016/s0143-974x(03)00106-8

[7] Sakino K, Nakahara H, Morino S and Nishiyama I: J Struct. Eng., ASCE, Vol. 130(2) (2004), pp.180-188.

[8] Liu Dalin and Gho W-M: Thin-Walled Strut., Vol. 43(8) (2005), pp.1131-1142.

[9] Lue DM, Liu J-L and Yen T: Journal of Constructional Steel Research, Vol. 63 (2007), pp.37-44.

[10] Ge HB, and Usami T: J Struct. Eng., ASCE, Vol. 118(11) (1992), pp.3036-3054.

[11] Lin TI, Huang CM and Chen SY: Journal of Chinse Institute of Civil and Hydraulic Engineering, Vol. 5(4) (1993), pp.377-386.

[12] Kitada T: Engineering Structures, Vol. 20 (1998), pp.347-354.

[13] Huang CS, Yeh YK, Liu GY, Hu HT, Tsai KC, Wen YT, Wang SH and Wu MH: J Struct. Eng., ASCE, Vol. 128(9) (2002), pp.1222-1230.

[14] Cai J and He ZQ: Journal of Constructional Steel Research, Vol. 62 (2006), pp.472-483.

[15] Cai J and Long Y-L: Journal of Constructional Steel Research, Vol. 65 (2009), pp.965-972.

[16] Huang Y, Long Y-L and Cai J: Steel and Composite Strutures, Vol. 8 (2008), pp.115-128.

[17] Ge H. B and Uami T: J Struct. Eng., ASCE, Vol. 122(10) (1996), pp.1169-1177.

[18] Sun WL. Behavior of Stiffened Concrete-filled Beam-Columns. (Master Thesis, National Taiwan University, China, 2000).

[19] Long Y-L and Cai J: Advanced Material Research, Vol. 255-260 (2011), pp.2584-2587.

[20] Schneider S. P: J Struct. Eng., ASCE, Vol. 124(10) (1998), pp.1125-1138.

[21] Han L. H: Concrete-filled steel tubular structures: Theory and practice (China Science Press, Beijing 2007), in Chinese.