Kinetic Characteristic of the Dust Particles around the Insulators

Article Preview

Abstract:

Contamination accumulation characteristic of the insulators depends on the kinetic characteristic of the particles moving around the insulators to a great degree. There are many forces acting on the particles due to the combined influence of the electric field, the air fluid field and the gravitational field. The main four forces, which are the polarization force, the electric field force, the steady-state drag force and the gravitational force, were analyzed. Their effects on the moving particles’ trajectories were studied by both experiments and numerical calculation. The results indicate that the polarization force acts where the strength of the electric field changes strongly. Once the particles are charged, the electric field force acts and can drive the particles moving along the electric field lines. When there is a strong wind, the steady-state drag force is dominant and the particles move with the wind. These results can better explain the contamination accumulation characteristic of different insulators under different operating conditions.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 455-456)

Pages:

271-277

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wang Bin, Liang Xi-dong, Zhang Yi-bo, Luo Bing, Li Zhen-yu, Liu Ying-yan, et al, Natural Pollution Test of Composite and Porcelain Insulators Under AC and DC stress, High Voltage Engineering, vol. 35, Sep. 2009, pp.2322-2328, doi: 1003-6520(2009).

Google Scholar

[2] Gao Hai-feng, Fan Ling-meng, Li Qing-feng, Su Zhi-yi, Li Yan, Li Xiao-lin, et al, Comparative Analysis on Pollution Deposited Performances of Insulators on the ±500 kV Gao-Zhao DC Transimission Line, High Voltage Engineering, vol. 36, Mar. 2010, pp.672-677, doi: 1003-6520(2010).

Google Scholar

[3] Li Zheng-yu, Liang Xi-dong, Wang Bin and Zhou Yuan-xiang, Natural Pollution Deposit Test of Polymeric Insulators Operated under DC Voltage, Power System Technology, vol. 31, Jul. 2007, pp.10-14, doi: 1000-3673(2007)14-0010-05.

Google Scholar

[4] Su Zhi-yi, Liu Yan-sheng, Comparison of Natural Contaminants Accumulated on Surfaces of Suspension and Post Insulators with DC and AC Stress in Northern China's Inland areas, Power System Technology, vol. 28, May. 2004, pp.13-17, doi: 1000-3673(2004).

Google Scholar

[5] M. Robinson, Electrostatic Precipitation. John Wiley & Sons Inc., NY, (1971).

Google Scholar

[6] William C. Hinds, Aerosol Technology -Properties, Behavior, and Measurement of Airborne Particles. John Wiley & Sons Inc., NY, Chichester, Brisbane, Toronto, Singapore, (1982).

Google Scholar

[7] Clayton Crowe, Martin Sommerfeld, and Yutaka Isuji, Multiphase Flows with Droplets and Particles. CRC Press LLC, Boca Raton, Boston, NY, Washington and London, (1998).

DOI: 10.1080/07373939908917667

Google Scholar

[8] Ravi S. Gorur, Edward A. Cherney and Jeffrey T. Burnham, Outdoor Insulators. Ravi S. Gorur, Inc., Arizona, (1999).

Google Scholar

[9] W. Lampe, T. Hoglund, et al, Long-term Test of HVDC Insulators under Natural Pollution Conditions at the Big Eddy Test Center, IEEE Transactions on Power Delivery, vol. 4, Jan. 1989, pp.248-258, doi: 0885-8977/89/0100-024.

DOI: 10.1109/61.19211

Google Scholar