A Hysteretic Current Controller for Active Power Filter (APF) with Constant Frequency

Article Preview

Abstract:

In accordance with the advantage of conventional hysteresis current control method, this paper advances a novel control method for APF. In conventional hysteresis current control, the hysteresis band (HB) is fixed and actual compensating current is limited in a fixed HB. Firstly, the connection between HB and switching frequency must be found correctly. Then, the variable hysteresis band current controller is designed according to the connection. Finally, the Matlab simulation results show that the switching frequency of VSI is held nearly constant and the proposed controller can track reference current well[1]. The problems of increasing switching losses and audible noise which happened in high-frequency state can be resolved in conventional hysteresis current control.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

308-312

Citation:

Online since:

February 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] S. Buso, S. Fasolo, L. Malesani, P. Mattavelli, A dead beat adaptive hysteresis current control, IEEE Trans. Ind. Appl. 2000, 36 (4): 1174–1180.

DOI: 10.1109/28.855976

Google Scholar

[2] Qiao C, Smedley K M. Three-phase active power filters with unified constant-frequency integration control[C]. Power Electronics and Motion Control Conference, 2000. Proceedings. PIE-MC 2000. The Third International, Vol: 2, Aug 2000:698-705.

DOI: 10.1109/ipemc.2000.884583

Google Scholar