The Theoretical Research of the Piezoelectric Fluid Spinning Top

Article Preview

Abstract:

In this paper, a mathematical model of the piezoelectric fluidic angular rate sensor is created. At first, starting from the Coriolis acceleration, obtain a comparison expression for the angular rate and the flow velocity. At second, according to the heat balance theory, solve a comparison expression for the thermal resistance wire current and flow velocity under the forced convection heat transfer condition. At last, obtain a comparison expression for the angular rate and the thermal resistance wire current. Thus a mathematical model of the piezoelectric fluidic angular rate sensor is created. Experiments prove that the average deviation between theoretical and experimental values is less than 10%.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

242-245

Citation:

Online since:

February 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Fuxue Zhang, Sensor Electronics, National Defence Industry Press, Beijing, 1991, p.170.

Google Scholar

[2] Hainan Cai, Zhaoying Zhou, A thermal resistance wires flow sensor research for measuring micro-flow rate, Measurement Technology, vol . 8, 1998, pp.13-15.

Google Scholar

[3] Yongbing Shen, Qingjun Li, Aijun Xiu, An airflow sensor research for the constant temperature thermal resistance wires, Journal of Harbin University of Science and Technology, vol. 4, 2000, pp.99-100.

Google Scholar