The Surface Characteristics of Exterior Wall External Insulation System with Foamed Glass in Weathering Resistance Test

Article Preview

Abstract:

A weathering resistance test was made to exterior wall external insulation systems with foamed glass decorated with coating and facing brick in this paper. The results show that the change of ambient temperature has large effect on the external insulation systems. Because of the phenomenon of stress concentration, there are many cracks in the windows position. On the other hand, the system decorated with facing brick has much less cracks than the system with coating, and its surface layer has no hollowing. So from the perspective of weathering resistance, the exterior wall external insulation systems with foamed glass decorated with facing brick is better than the system decorated with coating.