An Economic Analysis and Calculation for Selecting of the Phase-Change Heat Storage Materials Used in the Roof with a Solar Energy Storage Ventilation Systems

Article Preview

Abstract:

the experiments set up a roof model with a solar energy heat storage ventilation. According to the actual demands of experiments, through an economic analysis it results the preliminary investment of the solar energy storage ventilationthe system is between 307~367Yuan/m2 by calculating a energy balance in some way and choosing some type of heat storage phase change materials with a suitable quantity to fit for the model.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 479-481)

Pages:

578-585

Citation:

Online since:

February 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] FELIX T. Solar furnaces for high-temperature processing [J]. Solar Energy, 1963, 7(3): 100-107.

Google Scholar

[2] TROMBE F, ALBERT LE PHAT V. Thousand kW solar furnace, built by the National Center of Scientific Research, in Odeillo (France) [J]. Solar Energy, 1973, 15(1): 57-61.

DOI: 10.1016/0038-092x(73)90006-6

Google Scholar

[3] ONG K S. A mathematical model of a solar chimney [J]. Renewable Energy, 2003, 23: 1047-1060.

Google Scholar

[4] MATHUR J, MATHUR S, ANUPMA. Summer-performance of inclined roof solar chimney for natural ventilation [J]. Energy and Buildings, 2006, 38(10): 1156-1163.

DOI: 10.1016/j.enbuild.2006.01.006

Google Scholar

[5] BASSIOUNY R, KORAH N. Effect of solar chimney inclination angle on space flow pattern and ventilation rate [J]. Energy and Buildings, 2009, 41(2): 190-6.

DOI: 10.1016/j.enbuild.2008.08.009

Google Scholar

[6] Yinping Zhang, Jianhong Ding, Xin Wang, et al. Influence of additives on thermal conductivity of shape-stabilized phase change material [J]. Solar Energy Materials and Solar Cells, 2006, 90(11): 1692-1702.

DOI: 10.1016/j.solmat.2005.09.007

Google Scholar

[7] Wei Xiao, Xin Wang, Liqun Zhang, et al. EXPERIMENTAL STUDY ON UNDERFLOOR AIR SUPPLY SYSTEM WITH AIR SOLAR COLLECTOR AND SHAPE-STABILIZED PCM [J]. Acta Energiae Solaris Sinica, 2008, 29(11): 1319-1323.(In Chinese)

DOI: 10.1115/isec2006-99023

Google Scholar

[8] Yecong He, Jie Zhou, Houhua Wang, et al. RESEARCH ON THE PERFORMANCE OF THE PHASE CHANGE MATERIAL WALLBOARD ROOM [J]. Acta Energiae Solaris Sinica, 2007, 28(10): 1085-1090. (In Chinese)

Google Scholar

[9] Baizhan Li, Chunlong Zhuang, Anzhong Deng, et al. Improvement of Indoor Thermal Environment in Light Weight Building Combining Phase Change Material Wall and Night Ventilation [J]. Journal of Civil,Architectural & Environmental Engineering, 2009, 31(3): 109-113. (In Chinese)

Google Scholar

[10] ARKAR C, MEDVED S. Free cooling of a building using PCM heat storage integrated [J]. Solar Energy, 2007, 81:1078-1087.

DOI: 10.1016/j.solener.2007.01.010

Google Scholar

[11] ARKARA C, VIDRIHB B, MEDVEDA S. Efficiency of free cooling using latent heat storage integrated [J]. International Journal of Refrigeration, 2007, 30(134-43.

Google Scholar

[12] MEDVED S O, ARKAR C. Correlation between the local climate and the free-cooling [J]. energy and Buildings, 2008, 40:429–437.

DOI: 10.1016/j.enbuild.2007.03.011

Google Scholar

[13] Jingyan Lu. Experimental Study on Solar Ventilating Technology [D]. Chongqing; Chongqing University, 2008. (In Chinese)

Google Scholar

[14] Haiting Cui, Feng Yang. Heat Storage technology and its application [M]. Beijing: Chemical Industry Press, 2004. (In Chinese)

Google Scholar

[15] Zengmin Li. Thermal Storage and Rejection of Solid Phase-Change Materials [D]. Chongqing; Chongqing University, 2002. (In Chinese)

Google Scholar

[16] Chunxiang Fang. The Study of Stabilized Phase Change Materials Used at Middling and Low Temperature [D]. Beijing; Beijing University of Technology, 2006. (In Chinese)

Google Scholar