p-HEMA Membrane Fabrication Applying Nanogold for Biochemical Sensor

Article Preview

Abstract:

A p-HEMA (poly-hydroxy ethyl methacrylic acid) membrane using alcohol oxidase deposited on a carbon screen printed electrode (SPE) as working electrode for amperometric transducer has been built for biochemical sensor. Acetophenon derivate has been applied to generate polymeric cross linking while ferrocene mediator has been added to wire the electrochemical reaction. The UV photocuring attached the membrane polymer onto the carbon SPE. This study has obtained that nanogold application enhanced the formaldehyde biosensor performance. Optimum result using cyclic voltametric (CV) mode in amperometric assay has been found by applying 1.6% acetophenon, 1% ferrocene, 7.7u alcohol oxidase and 0.2% nanogold in phosphate buffer of pH 7.2 at 500s UV photocure.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 488-489)

Pages:

1530-1534

Citation:

Online since:

March 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] J.J. Baschuk and X. Li. J. Power Sources Vol. 86 (2000), p.181.

Google Scholar

[2] D. Chu and R. Jiang. J. Power Sources Vol. 81 (1999), p.128.

Google Scholar

[3] H.S. Chu, C. Yeh and F. Chen. J. Power Sources Vol. 123 (2003), p.1.

Google Scholar

[4] M.P. Hogarth, J. Munk, A.K. Shukla and A. Hamnett. J. Appl. Electrochem. Vol. 24 (1994), p.85.

Google Scholar

[5] Z. Qi and A. Kaufman. J. Power Sources Vol. 113 (2003), p.37.

Google Scholar

[6] Y.G. Yoon, G.G. Park, T.H. Yang, J.N. Han, W.Y. Lee and C.S. Kim. Int. J. Hydrogen Energy Vol. 28 (2003), p.657.

Google Scholar

[7] M.B. Ali, Y. Korpan, M. Gonchar, A. El'skaya, M.A. Maaref, N.J. Renault and C. Martelet. Biosens. Bioelec. Vol. 22 (2006), p.575.

Google Scholar

[8] E.A.H. Hall, M. Preuss, J.J. Gooding and M. Hammerle. Exploring sensors to monitor some environmental discharges. In: D.P. Nikolelis, U.J. Krull, J. Wang and M. Mascini, (Eds. ). Kluwer, Dordreht Vol. 38 (1998), p.227.

Google Scholar

[9] R. Kataky, M.R. Bryce, L. Goldenberg, S. Hayes and A. Nowak. Talanta Vol. 56 (2002), p.451.

Google Scholar

[10] O. Smutok, B. Ngounou, H. Pavlishko, G. Gayda, M. Gonchar and W. Schuhmann. Sens. Actuators B Vol. 113 (2006), p.590.

DOI: 10.1016/j.snb.2005.07.055

Google Scholar

[11] W. Vastarella and R. Nicastri. Talanta Vol. 66 (2005), p.627.

Google Scholar