The Adhesion Testing and Analysis for NiCr/NiSi Thin-Film Sensor

Article Preview

Abstract:

By the method of orthogonal experiment, with different sputtering power, sputtering pressure, sputtering time and substrate bias, 9 NiCr-NiSi thin-film thermocouples with different properties were prepared on the rake face of different cutting tools. With WS-2005 coating adhesion automatic scratch tester, the adhesion between the thin-film and the cutting tools were tested, and the test results was analyzed by range analysis. Analysis results show that, among four sputtering factors, substrate bias is the most important factor which influenced the thin-film adhesion. In a certain range, increasing the substrate negative bias voltage value can enhance the adhesion of thin-film. Subsequently, the range analysis result was verified by test. The best set of parameters was selected among all of the orthogonal test results, with other parameters unchanged except substrate negative bias, which was increased to -110V.And that, the adhesion value of NiCr and NiSi film was increased by 3.2N and 1.5N around individually.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 490-495)

Pages:

3748-3752

Citation:

Online since:

March 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zeng qiyong, Sun Baoyuan: Development of NiCr/NiSi thin-film thermocouple sensor for cutting temperature measurement, The 6th International Symposium on Test and Measurement. 1(2005), pp.89-96.

DOI: 10.1109/wcica.2006.1713610

Google Scholar

[2] Zeng Qiyong, Sun Baoyuan, Deng Xinlu, et al. A new fabrication method of NiCr/NiSi thin-film thermocouple sensor for workpiece temperature measurement in chemical explosive material machining, Conference Proceedings of The Sixth world Congress on Intelligent Control and Automation. 1(2006).

DOI: 10.1109/wcica.2006.1713610

Google Scholar

[3] Ali Basti, Toshiyuki Obikawaa and Jun Shinozukab: Tools with built-in thin-film thermocouple sensors for monitoring cutting temperature, International Journal of Machine Tools & Manufacture. 23(2007), pp.793-798.

DOI: 10.1016/j.ijmachtools.2006.09.007

Google Scholar

[4] Jehnming Lin, Shinn-Liang Lee, Cheng-I Wang: Estimation of cutting temperature in high speed machining, Journal of Engineering Materials and Technology. 12(1992), pp.289-296.

Google Scholar

[5] Marcio Bacci da Silva, James Wallbank: Cutting temperature prediction and measurement methods-review, Journal of Material Processing Technology. 28(1999), pp.195-297.

DOI: 10.1016/s0924-0136(98)00395-1

Google Scholar

[6] Qiu Tiebing: Experimental design and data processing(China Science and Technology University Press, Beijing2008), pp.124-135, in chinese.

Google Scholar

[7] Zhao Xuemin. Experimental design method(Science Press, Beijing2006), pp.213-232, in chinese.

Google Scholar

[8] T. Ueda, A. Hosokawa, A. Yamamoto: Measurement of grinding temperature using infrared radiation pyrometer with optical fibre. 4 (1986), pp.247-251.

DOI: 10.1115/1.3187074

Google Scholar

[9] Xu Jun, Ma Tengcai, Lu Wenqi. A new method for thin-film deposition—faced microwave electron cyclotron resonance plasma source enhanced direct-current magnetron sputtering, Chinese Physics Letter, 17(2000), pp.586-588.

DOI: 10.1088/0256-307x/17/8/015

Google Scholar

[10] Ohring M. The Material Science of Thin Films(Academic Press, Boston1992), pp.154-167.

Google Scholar