Abstract:

Glucose oxidase sensor is one of the best methods for measuring small amounts of glucose; this sensor can be modified using colloidal gold nanoparticles as complementary substance in the electrode structure with the aim of increasing efficiency. In this article, the colloidal gold nanoparticles (24 nm) were used to construct the two electrodes. The first electrode (Au/CP) was constructed of 100 mg carbon graphite powder, 36 µl paraffin oil and 300 µl colloidal gold nanoparticles. The second electrode (Au/CILE) was constructed of 100 mg carbon graphite powder, 36 µl paraffin oil, 300 µl colloidal gold and 50 mg ionic liquid oppf6. To evaluate the performance of each electrode and to prepare of bio sensor, these were covered by solution of 10 mg glucose oxidase and 1 ml phosphate buffer. The bio sensors were test with 0.8 mM glucose solution. By comparing the amount of AMP and the transfer time for both, the according results, the effect of colloidal gold nanoparticles on the increasing conductivity, sensitivity and stability biosensor, was determined.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

17-20

Citation:

Online since:

March 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] A. Sadona, Biosensors: Kinetics of Binding and Dissociation using Fractals, 2003, Elsevier, 1stEd., 1-2, Mississippi, USA.

Google Scholar

[2] A. Sanada, Fractal Binding and Dissociation Kinetics for Different Biosensor Application, 2005, Elsevier, 1stEd., 269-270, Mississippi, USA.

Google Scholar

[3] N. Ganesan, A. Gadar, M. Paranjape, J. Currie, Gold layer-based dual crosslinking procedure of glucose oxidase with ferrocene monocarboxylic acid provides a stable biosensor, Analytical Biochemistry, 343 (2005) 188-191.

DOI: 10.1016/j.ab.2005.04.018

Google Scholar

[4] A. Pereira, F. Fertonani, G. Neto, L. Kubota, H. Yamanaka, Reagentless biosensor for isocitrate using one step modified Pt-Ir microelectrode, Talanta, 53 (2001) 801–806.

DOI: 10.1016/s0039-9140(00)00566-x

Google Scholar

[5] A. Fang, H. Ng, S. Li, A high-performance glucose biosensor based on monomolecular layer of glucose oxidase covalently immobilized on indium-/tin oxide surface, Biosensors and Bioelectronics, 19 (2003) 43-49.

DOI: 10.1016/s0956-5663(03)00133-7

Google Scholar

[6] M, Tasi, Y. Tasi, Adsorption of glucose oxidase at platinum-multiwalled carbon nanotube-alumina-coated silica nanocomposite for amperometric glucose biosensor, Sensors and Actuators B: chemical, 141 (2009) 592-598.

DOI: 10.1016/j.snb.2009.06.016

Google Scholar

[7] A. Gopalan, K. Lee, D. Ragupathy, S. Lee, J. Lee, An electrochemical glucose biosensor exploiting a polyaniline grafted multiwalled carbon nanotube/perfluorosulfonateio- nomer–silica nanocomposite, Biomaterials, 30 (2009) 5999–6005.

DOI: 10.1016/j.biomaterials.2009.07.047

Google Scholar

[8] M. Xue, Q. Xu, M. Zhou, J. Zhu, In situ immobilization of glucose oxidase in chitosan–gold nanoparticle hybrid film on Prussian Blue modified electrode for high-sensitivity glucose detection, Electrochemistry communications, 8 (2006) 1468-1474.

DOI: 10.1016/j.elecom.2006.07.019

Google Scholar

[9] Y. Lei, X. Yan, J. Zhao, Y. Song, N. Luo, Y. Zhang, Improved glucose electrochemical biosensor by appropriate immobilization of nano-ZnO, Colloids and Surfaces, B: Biointerfaces, 82 (2011) 168–172.

DOI: 10.1016/j.colsurfb.2010.08.034

Google Scholar

[10] X. Zhang, H. Ju, J. Wang, Sensors, Biosensors and Their Biomedical Applications, 2008, Elsevier, 1stEd., 547-548, New York, USA.

Google Scholar

[11] J. Lin, Ch. He, Y. Zhao, Sh. Zhang, One-step synthesis of silver nanoparticles/carbon nanotubes/chitosan film and its application in glucose biosensor, Sensors and Actuators B: Chemical, 137 (2009) 768–773.

DOI: 10.1016/j.snb.2009.01.033

Google Scholar

[12] S. Zhang, N. Wang, H. Yu, Y. Niu, Ch. Sun, Covalent attachment of glucose oxidase to an Au electrode modified with gold nanoparticles for use as glucose biosensor, Bioelectrochemistry, 67 (2005) 15-22.

DOI: 10.1016/j.bioelechem.2004.12.002

Google Scholar

[13] X. Luo, J. Xu, Y. Du, H. Chen, A glucose biosensor based on chitosan–glucose oxidase–gold nanoparticles biocomposite formed by one-step electrodeposition, Analytical Biochemistry, 334 (2004) 284-289.

DOI: 10.1016/j.ab.2004.07.005

Google Scholar

[14] C. Ostiguy, G. Lapointe, L. Menard, Y. Cloutier, M. Trottier, M. Boutin, M, Antoun, Ch. Normand, Nanoparticles: Actual knowledge About occupational Health and safety Risks and Prevention Measures, 2006, Irsst, 1stEd., 1-2, Montreal, Canada.

Google Scholar

[15] S. Liu, H. Ju, Reagent less glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste Electrode, Biosensors and Bioelectronics, 19 (2003) 177-183.

DOI: 10.1016/s0956-5663(03)00172-6

Google Scholar

[16] X. Liu, X. Zeng, N. Mai, Y. Lin, B. Kong, Y. Li, W. Wei, Sh. Luo, Amperometric glucose biosensor with remarkable acid stability based on glucose oxidase entrapped in colloidal gold-modified carbon ionic liquid electrode, Biosensors and Bioelectronics, 25 (2010).

DOI: 10.1016/j.bios.2010.04.045

Google Scholar

[17] Y. Wu, Sh. Hu, Direct electrochemistry of glucose oxidase in acolloid Au–dihexadecylphosphate composite film and its application to develop a glucose biosensor, Bioelectrochemistry, 70 (2007) 335-341.

DOI: 10.1016/j.bioelechem.2006.05.001

Google Scholar

[18] F. Kurniawan, New Analytical Applications of Gold Nanoparticles, Faculty of Chemistry and Pharmacy, 2008, 1stEd., 12-13, Regensburg, Germany.

Google Scholar