Battery Capacity Evaluation Research on Wind\Battery Hybrid Generation System

Article Preview

Abstract:

Battery capacity evaluation is a key work in wind\battery hybrid generation system optimization. Here a research about battery capacity evaluation of wind\battery hybrid generation system is made and a new way to evaluate the capacity is given. First, common evaluation methods such as integration peak value method are introduced. Then energy conversion constraints analysis in wind\battery hybrid generation process is given. Fake charge problem existed in integration peak value method is described comprehensively. At last, a new method to evaluate the battery capacity is put out.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 512-515)

Pages:

1022-1026

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Changqing Gui. Sealed Gel-VRLA Battery: Energy storage equipment for wind energy and solar energy. CHINA ELECTRICAL EQUIPMENT INDUSTRY. 2007(09) P11

Google Scholar

[2] Chen wei. Applying research of storage batteries in photovoltaic system. Chinese Labat Man. 2006(1).P4

Google Scholar

[3] Wang Xiaohua Zhang Dongfeng. Design and economic estimation of standing-alone household wind/PV generation system. TRANSACTIONS OF THE CHINESE SOCIETY OF AGRICULTURAL ENGINEERING. 2008(10)P45-47

Google Scholar

[4] ZHENG Suo-zhen. Wind Power and PV Power Electric Generating System Is best Reasonable Independent Power-supply System. MECHANICAL MANAGEMENT AND DEVELOPMENT . 2008(06)P52-55

Google Scholar

[5] Qi Zhiyuan Wang Shengtie Tian Guizhen. COORDINATION CONTROL OF WIND/PV HYBRID SYSTEM. ACTA ENERGIAE SOLARIS SINICA  2010 31(5).

Google Scholar

[6] GU Min-an,LIU Yong-sheng. Deployment of a wind-solar hybrid power system in Nanhui District of Shanghai. ELECTRIC POWER. 2011 44(3)

Google Scholar

[7] Prasad R A, Natarajan E. Optimization of integrated photovoltaic-wind power generation systems with battery storage[J]. Energy,2006(31):1943-1954

DOI: 10.1016/j.energy.2005.10.032

Google Scholar

[8] Nelson D B, Nehrir M H, Wang C. Unit sizing and cost analysis of stand-alone hybrid wind/PV/fuel cell power generation systems[J]. Renewable Energy,2006(31):1641-1656

DOI: 10.1016/j.renene.2005.08.031

Google Scholar

[9] Koutroulis E, Kolokotsa D, Potirakis A, et.al. Methodology for optimal sizing of stand-alone photovoltaic/wind-generator systems using genetic algorithms[J]. Solar Energy,2006(80):1072-1088

DOI: 10.1016/j.solener.2005.11.002

Google Scholar

[10] X. Y. Wang, D. Mahinda Vilathgamuwa,Determination of Battery Storage Capacity in Energy Buffer for Wind Farm[J].IEEE TRANSACTIONS ON ENERGY CONVERSION. 2008,vol23(3):868-878

DOI: 10.1109/tec.2008.921556

Google Scholar