Buckling Analysis on Large Wind Turbine Tower

Article Preview

Abstract:

The buckling of 2.5MW horizontal axis wind turbine tower tube (5.8m*3.2m*95.2m) is studied by theoretical analysis and numerical simulation. The buckling critical value of tower under axial force is found by theoretical method. The buckling modal of tower under axial force, wind pressure, bending moment and lateral force is simulated by ANSYS software. The buckling of tower with opening and frame at the bottom is also simulated by ANSYS software. The results show that both load and opening have influence on buckling performance, different load and opening have different impact to buckling of tower tube.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 512-515)

Pages:

604-607

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Kim S E: Thin-walled strutures,Vol.40(2002),pp.329-353

Google Scholar

[2] Shilin Zhao,Deyuan Li: ACTA ENERGIAE SOLARIS AINICA,Vol.31(2010) (In Chinese)

Google Scholar

[3] Buckling strength of shells,DNV-RP-C202 (2002)

Google Scholar

[4] Guideline for the Certification of Wind Turbines,GL 2010 (2010)

Google Scholar

[5] Structural Steelwork analysis of safety against buckling shell,DIN 18800-4 (1990)

Google Scholar

[6] Timoshenko,in: Elastic stability theory,edtied by Science Publication,Beijing(1985),in press.

Google Scholar