The Experiment Study on Tank Capacity Measurement with Flowmeter

Article Preview

Abstract:

To analyze the accuracy in the volume measurement of vertical tank with flowmeter, experiment based on volume measurement device of standard flowmeter method with different flowmeter is made in this paper. The capacity values of different liquid level in tank which are used to fitting and correcting the actual results of continuous measurement are calibrated by standard flowmeter and level gauge. Fitting coefficient can be used to analyze the accuracy of other measurement. Experiment results show that it is feasible to measure the capacity of vertical tank by standard flowmeter with high measure accuracy and small measure error.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 516-517)

Pages:

1105-1108

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yuying Lian, "Capacity Measurement Techniques", China Metrology Publishing House (2006) (in Chinese).

Google Scholar

[2] Guowei Liang, Jian Sheng, Process Automation Instrumentation, Vol. 22(2001), p.46 (in Chinese).

Google Scholar

[3] JJG 643-200, "Verification Regulation of master meter method for standard flow device" (in Chinese).

Google Scholar

[4] Jeffrey Travis, Jim Kring: Labview for Everyone (Prentice Hall, 2007).

Google Scholar