Simulation Calculation of Spiral Condenser about Refrigerant System

Article Preview

Abstract:

This paper establish a simulation program about the spiral condenser based on theoretical behavior of thermal parameters used R134a as refrigerant, analysis the influence of heat transfer area on refrigerant performance, and calculate best length of condenser heat transfer tube. The results show that the tread of coefficient of performance(COP) and cooling capacity of the system is similar along with the heat transfer tube length, and the research for the optimization design about spiral condenser heat exchanger provides the theoretical support.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 516-517)

Pages:

1192-1195

Citation:

Online since:

May 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Luu M, Bergles AE. Enhancement of horizontal in-tube condensation of refrigerant-113 [J]. ASHRAE Trans. 1980. 86: 293-312.

Google Scholar

[2] Boyko LD, Kruzhilin GN. Heat transfer and hydraulic resistance during condensation of steam in a horizontal tube and in a bundle of tubes [J]. Int J Heat Mass Transfer 1967 (10): 361-73.

DOI: 10.1016/0017-9310(67)90152-4

Google Scholar

[3] Cavallini A, Zecchin R. High velocity condensation of organic refrigerants inside tubes [J]. In: Proc. 8th Int.Cong. Refrigeration, vol. 2, Brussels, Belgium, 1971:193-200.

Google Scholar

[4] Cavallini A, Doretti L. Condensation of new refrigerants inside smooth and enhanced tubes [J]. In: Proc. 19th Int. Cong. Refrigeration, vol. IV, Hague, The Netherlands, 1995: 105-14.

Google Scholar

[5] Yu J, Koyama S. Condensation heat transfer of pure refrigerants in microfin tubes[J]. In: Proc. Int. Refrigeration Conference at Purdue Univ.West Lafayette, USA, 1998: 325-30.

Google Scholar

[6] Shikazono N, Itoh M, Uchida M, Fukushima T, Hatada T. Predictive equation proposal for condensation heat transfer coefficient of pure refrigerants in horizontal microfin tubes [J]. Trans Jap Soc Mech Engrs 1998, 64:196-203 [in Japanese].

DOI: 10.1299/kikaib.64.196

Google Scholar

[7] Kedzierski MA, Goncalves JM. Horizontal convective condensation of alternative refrigerants within a micro-fin tube [J]. J Enhanced Heat Transfer 1999; 6(2-4): 161–78.

DOI: 10.1615/jenhheattransf.v6.i2-4.90

Google Scholar

[8] Huifan zheng, The Performance Research of the Solar Ejector/Electric Compression Combined Refrigeration System [D]. Xi'an university of architecture and technology, 2009.

Google Scholar

[9] Huifan Zheng, Xiaowei Fan, Angui Li. Experimental research about solar ejector refrigerant based on the climate condition in the zhengzhou region[J]. Acta energiae solaris sinica. 2011. 32(8):1169-1173.

Google Scholar