A Calculation Method of the Optimal Initial Steam Pressure of the Power Plant Based on Model Analysis

Article Preview

Abstract:

The shortage of control system for the air-cooling unit is the lack of theoretical guidance and relative operating experience in the selection of operating mode. The mathematical model is built to optimize the initial steam pressure of the air-cooling unit with the method of systemic analysis. Through calculation of air-cooling unit NZK600-16.7/537/537-Ⅰ, the optimal initial steam pressure curves in different work conditions are obtained. The analysis will improve the optimal system-wide control theory of air-cooling power plant. Limitation of the initial steam pressure curve provided by manufactory is also analyzed in this paper.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 516-517)

Pages:

824-829

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Weixing Liu, Yong Lin "The designation and application of direct air-cooling system in coal fired power engineering", Science and engineering of electric power [J] No.3, 2004, (3): 72-74.

Google Scholar

[2] Wei Li, Haoren Ren. "Energy consumption analysis system for 300MW Coal-fired power unit", Proceedings of the CSEE [J], 2002, 22(11):153-155.

Google Scholar

[3] Zhang Chunfa, "On-line monitoring and instructing system for thermal system, equipments and operation of high capacity unit in coal-fired power plant", Turbine technology [J], Vol. 43, No. 3, pp.129-132, 2001.

Google Scholar

[4] Chunfa Zhang, Decheng Zhang, Bao Zhang etc. "The thermodynamic system , equipments and energy saving operating on-line monitoring and guidance system of coal-fired power unit" ,Technology of steam turbine [J], 2001, 43(3):129-132.

Google Scholar

[5] Naimanov, O. S, "Features of the selection of initial steam pressure of geothermal power stations with one and two evaporation stages", Thermal Engineering[J], Vol. 33, No. 2, pp.79-82, Feb, 1986.

Google Scholar

[6] Aminov.R., Chertykov, "Choice of optimal stage of initial steam pressure in heat-generating power units", Tyazheloe Mashinostroenie [J], No. 8, pp.18-19, Aug.1992.

Google Scholar

[7] Haoren Ren, Li Wei. "Analysis of the operating index target value of coal-fired power unit under variable condition", Proceedings of the CSEE [J], 1999,19(9): 50-52,56.

Google Scholar

[8] Zuqing Cao. "The variable conditioning characteristics of steam turbine"[M].Beijing publishing house of water conservancy and electric power, 1991.

Google Scholar

[9] Chunfa Zhang, "A steam-water distribution matrix equation of the whole thermal system for coal-fired power plant and its general construction regulations", 1999 International Joint Generation Conference, U.S.A, New York, pp.497-503, 1999 ASME.

Google Scholar