Study on Replacement of EHC Using HVOF Sprayed Coatings

Article Preview

Abstract:

Environmental protection and worker safety measures against the extensively used hard chrome plating (EHC) is becoming more stringent, which leads to the development and application of alternative technology. As one of the most promising replacement technology of EHC, WC/Co coatings deposited by High Velocity Oxygen Fuel (HVOF) have well performances in corrosion and wear resistance. The paper analyzed technical characteristics, property and cost of EHC and HVOF deposited WC-Co coatings, while results show that performance of HVOF sprayed WC-Co coatings is superior or equal to EHC with much higher expense, so current replacement of EHC by HVOF centers airplane and military arm field which have relatively higher profit.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 518-523)

Pages:

3984-3988

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Bruce D.Sartwell, Keith O.legg, Jerry Schell, John Sauer, Paul Natishan, etc. Replacement of chromium eelectroplating on gas turbine engine components using thermal spray coatings. Naval research laboratory, 2006, pp.3-4.

Google Scholar

[2] T.Sahraoui, N.E. Fenineche, G. Montavon, C. Coddet.Wear behavior of HVOF Sprayed WC-12%Co coatings vs. Hard Chrome Plating.Proceedings of the 2004 International Thermal Spray conference, OSAKA, Japan, 2004.

DOI: 10.31399/asm.cp.itsc2004p0488

Google Scholar

[3] G.Matthaus, J.Henry, D.Ackermann. Further developments in internal diameter HVOF application of WC-CoCr for hard chrome replacement in critical applications such as landing gear. Proceedings of the 2009 International Thermal Spray Conference, Las Vegas, USA, pp.722-724.

DOI: 10.31399/asm.cp.itsc2009p0722

Google Scholar

[4] Keith O.Legg, Bruce D.Sartwell, Jean-Gabriel Legoux, Montia Nestler, Christopher Dambra, ETC. Investigation of plasma spray coatings as an alternative to hard chrome plating on internal surfaces. Report of naval research laboratory, 2006, pp.1-2.

Google Scholar

[5] Bruce D.Sartwell, Keith O.legg, Jerry Schell, John Sauer, Paul Natishan, etc. Validation of HVOF WC/Co thermal spray coatings as a replacement for hard chrome plating on aircraft landing gear. Report of naval research laboratory, 2004, pp.254-255.

DOI: 10.21236/ada607046

Google Scholar