Parameters Influence of 150000m3 Base Isolation Storage Tank with Floating Roof

Article Preview

Abstract:

Selecting 150000m3 storage tank as research object, the base isolation system was introduced and allowing for the impact of floating roof to study the seismic response of vertical storage tanks. The finite element models were established by using ADINA. The damping rate of floating-roof storage tank in multi-direction seismic excitation, and the damping rate of base isolation vertical storage tank in different isolation layer damping ratio, isolation periods were calculated respectively and comparative analyzed. The results indicate that: the damping rate of hydrodynamic pressure in three-dimensional seismic excitation is less than that of unidirectional, little change in the damping rate of base shear and overturning moment, sloshing wave height control action is not obvious. With the isolation period and isolation layer damping ratio increases, the damping rate of base shear, overturning moment, and hydrodynamic pressure are all increase. Isolation measures can not effectively control the sloshing wave height, and the isolation period and the isolation layer damping ratio have a reasonable optimization range.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 524-527)

Pages:

1839-1843

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Dechao Wen, Zhaochang Zheng, Huanchun Sun. Storage tank seismic research progress. [J] Advances in Mechanics,1995,25(1): 60-76. In Chinese.

Google Scholar

[2] Liang B,Tang J X.Vibration studies of base isolated storage tanks[J] Computers and structures,1994,52:1051-1059.

DOI: 10.1016/0045-7949(94)90089-2

Google Scholar

[3] Haiyan Mu,Sesimic Response Analysis and Passive-Control Technique Research of Liquid-Storage Elevated Tank[D]Harbin Institute of Technology,2006.6. In Chinese.

Google Scholar

[4] Hongnan Li. Structure of multi-dimensional seismic theory and design method [M].Beijing: Science Press, 1998. In Chinese.

Google Scholar

[5] Zhen Wang, Three Dimensional Earthquake Response Analysis and Test Study of Unanchored Liquid Storage Tank [D]Harbin Engineering University,2006. In Chinese.

Google Scholar

[6] Jiangang Sun, Zhen Wang, Yu Yang, Ying Sun, Finite element analysis of 3D seismic response of unanchored liquid storage tanks [J] Journal of Earthquake Engineering and Engineering Vibration, 2008.5(28)122-132. In Chinese.

Google Scholar

[7] Ying Sun, Lifu Cui, Jiangang Sun, Yinghua Zhao, Base Isolation Numerical Analysis of Vertical Storage Tanks with Floating Roof under Three Dimensional Excitation[J]2011.04. In Chinese.

Google Scholar

[8] Jiangang Sun, Isolation of Large Vertical Storage Tank—Theory, Method, Test.[M]Beijing,Science Press,2009. In Chinese.

Google Scholar

[9] GB50341-2003,Code for design of vertical cylindrical welded steel oil tanks[M] China Planning Press. In Chinese.

Google Scholar

[10] Bathe K J, AdinaTheoretical Manual(Ⅰ)[R]. 1999:201-210

Google Scholar