Energy Consumption Analysis of Coal-Fired Power Plant with CO2 Capture System Based on Solar Energy

Article Preview

Abstract:

To the question of high energy consumption and cost about coal-fired power plant CO2 emission,this paper from the coupling mechanism research of solar energy collection system,amidogen CO2 emission reduction system and coal-fired power plant thermal system ,as well as systematic integration and optimization ,and then based on equivalent heat drop method ,It analyses the thermal economy changes about this new type integration system at THA, 75% THA, 50% THA conditions corresponding to the different carbon capture rate of the four programs .Finally,it works out the unit thermal economy variation tendency at different rate of carbon capture,its thermal economy relative degree increase if capture rate increase .On this basis ,this paper optimizes the integration system in order to achieve low power consumption, low cost of CO2 emissions for reference.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 524-527)

Pages:

2360-2367

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Weilong Zhong.Study on CO_2 Chemical Absorption Technology [D].Hangzhou: Zhejiang University, 2008.In Chinese

Google Scholar

[2] Gang Xu.Comprehensive Assessment and Multi-objective Optimization for Energy System with CO_2 Capture [D].Beijing: Institute of Engineering Thermo physics, Chinese Academy of Sciences, 2007, 12.In Chinese

Google Scholar

[3] Weichu Liao, Xiufang Ke.Application of Solar Energy in Medium & High Temperature Steam Generation [J].Energy of China, 2008, 26(150): 328-331.In Chinese

Google Scholar

[4] Jun Wang, Yaoming Zhang, Deyou Liu, Liguo Sun, Cuicui An.DSG technology in groove solar thermal power generation in practice [J].Solar Energy, 2007, 3: 20-22.In Chinese

Google Scholar

[5] Wanchao Lin.Theory of thermal energy power plant system[M].Xi'an: Xi'an Jiaotong University, 1994.In Chinese

Google Scholar

[6] Singh D, Croiset E, Douglas P, Douglas M.Techno economic study of CO2 capture from an existing coal-fired Power Plant: MEA scrubbing vs O2/CO2 recycle combustion.Energy Conversion & Management.2003, 44: 3073-3091.

DOI: 10.1016/s0196-8904(03)00040-2

Google Scholar

[7] Article Habakih, Perera J M, Kentish S E, et a1.CO2 absorption behavior with a novel random packing: super miniring[J].Separation Science and Technology, 2007, 42(4): 701-7l6.

DOI: 10.1080/01496390601174075

Google Scholar

[8] Zhi wu Liang, Tontiwachw Uthiku L P, Idem R.Simulation of the effects of lean loading and flue Gas temperature(with and without a saturator)on energy require ends for absorption of CO2 in 30wt MEA solution using ProMax2.0[A].58th Canadian Chemical Engineering Conference[C].Ottawa, Canada: 2008, 20-22.In Chinese

Google Scholar

[9] Bin Huang, Shisen Xu, Shiwang Hao.Industrial Test of CO_2 Capture in Huaneng Beijing Coal-fired Power Station [J].Proceedings of the CSEE, 2009, 29(17): 14-15.In Chinese

Google Scholar