Study on the Structural and Aseismatical Performance of Multi-Storey Ancient Chinese Timber Structure Shangyou Tower of Palace Style

Article Preview

Abstract:

Based on the rich previous experimental data, the multi-storey ancient Chinese timber structure shangyou tower of palace style was studied. ANSYS10.0 software was used to establish the finite element models. One finite element model of large wooden frame was established by applying semi-rigid spring element to simulate the joint of mortise-tenon, tou-kung and the connection on column foot in the real wooden structure. The other finite element model of antique building corresponding to the finite element model above was established. The first 10 inherent frequencies and vibrations of the two models were obtained by the method of Block Lanczos with full transient analysis. The model displacement and acceleration time history curves were obtained by taking the two models subjected to El-Centro ground motion, Taft ground motion and Lanzhou artificial ground motion excitation. By the results analysis of the two models, it can be find that the vibration isolation performance of the ancient Chinese timber structure mainly manifests in the column foot, tenon and mortise connection and the tou-kung layer.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 535-537)

Pages:

2012-2016

Citation:

Online since:

June 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] D.F. Gao, H.T. Zhao, J.Y. Xue, P.C. Zhang. World Earthquake Engineering, Vol. 19(2003), pp.1-10. (In Chinese)

Google Scholar

[2] J. Li (Dynasty Song). Ying-tsao fa-shih. (Commercial Press, Shanghai 1950). (In Chinese)

Google Scholar

[3] M.H.Yu. Journal of Xi'an JiaoTong University, Vol. 37(2005), pp.78-89. (In Chinese)

Google Scholar

[4] G.R.Li, E.D. Guo, M.Zhu. Earthquake Engineering and Engineering Vibration, Vol. 24(2004), pp.68-72. (In Chinese)

Google Scholar

[5] Z.R. Guo. 15-th of the architect's portable handbook.( China Building Industry Press, Beijing 2007). (In Chinese)

Google Scholar

[6] J.Su. Northwestern Seismological Journal, Vol.30(2008), pp.239-244. (In Chinese)

Google Scholar

[7] D.P. Fang, M.H.Yu, S.Iwasaki, H. Hikosaka. Engineering Mechanics, Vol.18(2001), pp.137-144. (In Chinese)

Google Scholar

[8] K. Yao, H.T. Zhao. Journal of Engineering Mechanics. Vol. 23 (2006), p.127~131. (In Chinese)

Google Scholar

[9] Tin-Loi F, Vimonsatit V. Engineering Structure, Vol. 18(1996), p.115~124.

Google Scholar

[10] T. Wang. Static analysis on ancient timber structures. (Cultural Relics Publishing House, Beijing 1992). (In Chinese)

Google Scholar

[11] W. S. King, W. F. Chen. Journal AISC, Vol. 30 (1993), p.130~140.

Google Scholar

[12] D.F. Gao, X.J. Ding, P.N. Cao. Journal of Earthquake Engineering and Engineering Vibration, Vol. 31(2011), p.108~114.

Google Scholar