Numerical Simulation of the 3D Turbulent Flow Field in a Cross-Flow Fan Used in the Air Conditioner

Article Preview

Abstract:

Aiming at a cross-flow fan used in some kind of air conditioner, the full field 3D model was built, and the numerical simulation of the inner turbulent flow under design condition is resented. The results display the characteristics of flow field in the cross-flow fan, especially the velocity field, pressure field and the velocity distributing before the evaporator. The results can provide basis for optimizing the fan design and the internal flow, and have important value of engineering applications in the increase of the overall performance in operation.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 538-541)

Pages:

462-465

Citation:

Online since:

June 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Tsurusaki, H., Tsujimoto, Y., Yoshida, Y . et al. Study of cross-flow fan internal flow by flow visualization[J]. Journal of Fluids Engineering, 1996, 39(3): 540-545.

DOI: 10.1299/jsmeb.39.540

Google Scholar

[2] Young J Moon, Yong Cho, Hyun-Sik Nam. Computation of unsteady viscous flow and aero acoustic noise of cross-flow fans[J]. Computers-Fluids, 2003, Vol. 32(3): 995-1015.

DOI: 10.1016/s0045-7930(02)00068-3

Google Scholar

[3] Miyamoto Hiroyuki, Nakashima Yukitoshi. Effects of splitter blades on the flows and characteristics in centrifugal impeller. JSME International Series, 1992, 35(2): 238-246.

DOI: 10.1299/jsmeb1988.35.2_238

Google Scholar

[4] Wan-Ho Jeon. A numerical study on the effects of design parameters on the performance and noise of a centrifugal fan. Journal of Sound and Vibration, 2003, Vol. 265: 221-230.

DOI: 10.1016/s0022-460x(02)01582-1

Google Scholar

[5] QIAN, Z .D, YANG, J D, HUAI, W X. Numerical simulation and analysis of pressure pulsation in Francis hydraulic turbine with air admission. Journal of Hydrodynamics, 2007, 4: 467-472.

DOI: 10.1016/s1001-6058(07)60141-3

Google Scholar

[6] M. Govardhan, K. Viswanath. Investigations on an axial flow fan stage subjected to circumferential inlet flow distortion and swirl. J. of Thermal Science, 1997, 4:241-250.

DOI: 10.1007/s11630-997-0003-8

Google Scholar

[7] LI Yang, OUYANG Hua, DU Zhao-hui. Experimental research on aerodynamic performance and exit flow field of low pressure axial flow fan with circumferential skewed blades. Journal of Hydrodynamic, 2007, 5:579-586.

DOI: 10.1016/s1001-6058(07)60156-5

Google Scholar

[8] Velarde-Sandra.Numerical Prediction of The Aerodynamic Tonal Noise in A Centrifugal Fan. Experimental Thermal and Fluid Science,2002, 26(5): 421-434.

Google Scholar