A Novel Three-Dimensional Gait Analysis System

Article Preview

Abstract:

Three-dimensional (3D) lower limb kinematic and kinetic analysis based on ambulatory measurements is introduced in this paper. We developed a wireless sensor system composed of a mobile force plate system, 3D motion sensor units and a wireless data logger. 3D motions of body segment and triaxial ground reaction force (GRF) could be simultaneously measured using the system, and the data obtained from sensor units on thighs, shanks and feet could be transferred to a personal computer by wireless local area network (LAN). An inverse dynamics method was adopted to calculate triaxial joint moments. The accuracy of kinematics and kinetics (joint moments) assessment is validated against results obtained from the stationary measurement system based on camera movement analysis and force plates.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

352-355

Citation:

Online since:

September 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Schepers, H.M., Koopman, H.F.J.M., Veltink, P.H., Ambulatory assessment of ankle and foot dynamics. IEEE Transactions on Biomedical Engineering (2007), 54 (5), 895-902.

DOI: 10.1109/tbme.2006.889769

Google Scholar

[2] Liu, T., Inoue, Y., Shibata, K., A wearable force plate system for the continuous measurement of triaxial ground reaction force in biomechanical applications. Measurement Science and Technology (2010), 20(8), no. 085804.

DOI: 10.1088/0957-0233/21/8/085804

Google Scholar

[3] Liu, T., Inoue, Y., Shibata, K., Development of a Wearable Sensor System for Quantitative Gait Analysis. Measurement (2009), 42(7), 20(8), 978-988.

DOI: 10.1016/j.measurement.2009.02.002

Google Scholar

[4] Brookner, E., Tracking and Kalman filtering made easy. John Wiley and Sons, Inc. (1998), New York.

Google Scholar

[5] Liu, T., Inoue, Y., Shibata, K., Shiojima, K., A Mobile Force Plate and Three-dimensional Motion Analysis System for Three-dimensional Gait Assessment, IEEE Sensors Journal (2012), 15(5), 1461-1467.

DOI: 10.1109/jsen.2011.2173763

Google Scholar

[6] Cutti, A.G., Giovanardi, A., Rocchi, L., Davalli, A., Sacchetti, R., Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors. Medical and Biological Engineering and Computing (2008), 46(2), 169-178.

DOI: 10.1007/s11517-007-0296-5

Google Scholar

[7] Davis III, R.B., Õunpuu, S., Tyburski, D., Gage, J.R., A gait analysis data collection and eduction technique. Human Movement Science (1991), 10 (5), 575-587.

DOI: 10.1016/0167-9457(91)90046-z

Google Scholar

[8] Zatsiorsky, Vladimir M., Seluyanov, V.N., The mass and inertia characteristics of the main segments of the human body. Biomechanics V-IIIB, Human Kinetics Publishers (1983), Chamapaign, IL, 1152-1159.

Google Scholar

[9] Bresler, B. and Frankel, J., The forces and moments in the leg during level walking. Trans. ASME (1950), 72, 27-36.

DOI: 10.1115/1.4016578

Google Scholar

[10] Eng, J.J., Winter, D.A., Kinetic analysis of the lower limbs during walking: What information can be gained from a three-dimensional model? Journal of Biomechanics (1995), 28(6), 753-758.

DOI: 10.1016/0021-9290(94)00124-m

Google Scholar