Analysis of End Crack in Boiler Tube

Article Preview

Abstract:

Boiler tube failures usually result in frequent forced outages, and ultimately in costly extended outages for major tubing replacement in a plant. There are several failure modes that may occur in a boiler tube, i.e. stress-corrosion cracking, pitting, water-side corrosion, fire-side corrosion, fatigue failure, overheating, dissimilar metal weld fatigue, mechanical fatigue and erosion. In this research the failure modes of boiler and its end cracks due to the dissimilar metal weld is analyzed. Hence data are collected and explored to determine the cause of failure and as a solution ceramic ferrule is suggested. The use of ceramic ferrule in boiler tube can eliminate the crack occurrence or delay the process due to thermal properties. The prevention of crack will reduce frequent maintenance and thus the cost of operation can be minimized.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

749-752

Citation:

Online since:

October 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Frederick M. Steingress, Low Pressure Boilers, 4th edition, American Technical Publishers, ISBN 0-8269-4417-5, (2001).

Google Scholar

[2] Frederick M. Steingress, Harold J. Frost and Darryl R. Walker, High Pressure Boilers, 3rd edition, American Technical Publishers, ISBN 0-8269-4300-4, (2003).

Google Scholar

[3] GS Harrison, D Penfold, MA Walker and JC Greene, Full Scale Boiler Rig Studies of Two-Phase Erosion-Corrosion in the Pressure Range 35-40, Central electricity generating board, (1985).

Google Scholar

[4] Allen S.B. Tam, John W.H. Price, Alan Beveridge, A maintenance optimisation framework in application to optimise power station boiler pressure parts maintenance, Journal of Quality in Maintenance Engineering. 13 (4) (2007) 364 – 384.

DOI: 10.1108/13552510710829461

Google Scholar

[5] The Materials Information Society, ASM HANDBOOK Failure Analysis and Prevention – Volume 11.

Google Scholar

[6] http: /www. steamcycle. com/boiler_tube. htm' Boiler Tube Failure Analysis, Jonas Inc., Downloaded 5 December, (2011).

Google Scholar

[7] D. Rezakhani, Corrosion Behaviours of Several thermal Spray Coatings Used on Boiler Tubes at Elevated Temperature Anti-Corrosion Methods and Materials,. 54(4) (2007) 237 -243.

DOI: 10.1108/00035590710762384

Google Scholar

[8] http: /www. azom. com/Details. asp?ArticleID=3303, "Zirconoa Toughned Alumina ZTA-Properties and Applications of ZTA by Dynamic Ceramic Ltd., Dynamic Ceramic, Precision Engineering Ceramic Solution, Downloaded 5 December, 2011. Zirconia Toughened Alumina ZTA - Properties and Applications of ZTA by Dynamic Ceramic Ltd.

DOI: 10.1002/9780470599730.ch28

Google Scholar

[9] Zirconia Toughened Alumina ZTA - Properties and Applications of ZTA by Dynamic Ceramic Ltd.

Google Scholar