Study on a New Setting Method of Distance Relay with Superconducting Fault Current Limiter Adapt in the Grid

Article Preview

Abstract:

Considerable attention is given towards developing Superconducting fault current limiter (SFCL) due to increasing short circuit levels in transmission lines, which itself imposes further changes on the measured impendence at the relaying point and causes significant impact on the lines’ relay protection, especially on the distance protection as the single-phase grounding fault occurs. In this paper, resistive superconducting fault current limiter connected to the grid is studied as the model to analysis how SFCL affects the grounded short-circuit impedance relay’s setting, then an new setting method of distance protection for the SFCL-equipped line is proposed. Finally, a power system model is built to analysis the theory by PSCAD / EMTDC simulation software. The results show that in the condition of using the impedance relays’ new setting method, impedance measurement error is greatly reduced, SFCL and line distance protection can work in coordination with each other properly.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 588-589)

Pages:

471-474

Citation:

Online since:

November 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Shateri, H. and S. Jamali, Comparing measured impedance by distance relay in presence of resistive and inductive Fault Current Limiters, in PowerTech, 2009 IEEE Bucharest. 2009. pp.1-6.

DOI: 10.1109/ptc.2009.5282269

Google Scholar

[2] Shateri, H. and S. Jamali, Measured impedance by distance relay for inter phase faults in presence of resistive Fault Current Limiter, in Power System Technology (POWERCON), 2010 International Conference on. 2010. pp.1-7.

DOI: 10.1109/powercon.2010.5666014

Google Scholar

[3] FAN Haihong, Predictive analysis of short-circuit current level of Jiangsu power grid [J]. East China Electric Power, 2000, 1(1): 24-25.

Google Scholar

[4] Shateri, H. and S. Jamali, Measured impedance by distance relay for inter phase faults in presence of inductive fault current limiter, in Power & Energy Society General Meeting, 2009. PES '09. IEEE. 2009. pp.1-7.

DOI: 10.1109/pes.2009.5275525

Google Scholar

[5] LIU Hualei, ZHANG Daozhuo. Improved setting method of distance Protection with the SSFCL. 2006, 30(2): 90-94.

Google Scholar

[6] HE Jiali, Power system protection principles and practical technology, Beijing: China Electric Power Press, 2009: 136-137.

Google Scholar

[7] LIU Wanshun, Huang Shaofeng, Xu Yuqin. Power system fault analysis, Beijing: China Electric Power Press, 2009: 101-102.

Google Scholar