Fracture Reason Analysis for Helical Gear Shaft of Converter Tilting Mechanism Senior Reducer

Article Preview

Abstract:

A steel works 210 tons basic oxygen furnace tilting mechanism senior reducer high-speed helical gear shaft fracture. In order to find fractured reason, the static strength analysis of helical gear shaft were conducted by the finite element analysis software ANSYS, get the amount of deformation and stress distribution of helical gear shaft. On the basis of this result, based on fatigue cumulative damage theory and the concept of fatigue failure ensure it is fatigue fracture. The results of Static strength analysis provides important data to calculate fatigue life of helical gear shaft by fatigue analysis software, and Provides a theoretical basis for reliability design of helical gear shaft.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 605-607)

Pages:

824-827

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yumin Pan. Steelmaking Equipment[M].BingJing: Metallurgical Industry Press,1977. (In Chinese)

Google Scholar

[2] Hongwen Liu. Mechanics of Materials[M]. BingJing: Higher Education Press.2004.1. (In Chinese)

Google Scholar

[3] RitehieR.O. Suresh5.Some considerations on fatigue crack closure at near threshold stress intensities due fracture surface morphology [J].Metallurgical Transations,1981,13A:937~40.

DOI: 10.1007/bf02642409

Google Scholar

[4] ESDU HIS.Endurance of high-strength steels [J].Issued August,2004:27~29.

Google Scholar

[5] Shaobian Zhao, Zhongbao Wang, Anti-Fatigue design: Methods and data [M].BingJing: China Machine Press.1977.

Google Scholar

[6] Hui Li, HongYan. The finite element analysis of 1.5MW wind generator helical gear shaft by ANSYS[J].Hoisting and Conveying Machinery.2010(6):20~22.

Google Scholar