Study on the Performance of Modified UASB Process Treating Sewage
Abstract:
Added the anaerobic contact oxidation fill area on traditional UASB reactor,the imitation domestic sewage was treated by this modified UASB process on this paper. The COD removal was studied by regulated temperature,hydraulic retention time(HRT) and the influent concentration; The stability of this reactor was studied by regulated pH value of inflow and effluent.The results show that,when regulated the inflow pH value about 7.5,and effluent pH by maintainned about 6.8-7.2,so ensure that the reactor operation was stable;when T=45±5°C,the COD removal can reach 92.8%; when the HRT was 10h,the COD removal is 76.8%~92%;when the inflow concentration were 500mg/L,750mg/L,1000mg/L,the average COD removal are 65.68%, 75.58% and 83.05%.
Info:
Periodical:
Pages:
2174-2178
Citation:
Online since:
December 2012