A Research and the Application of a New Graphite Grounding

Article Preview

Abstract:

As the corroded metal grounding usually has a high resistance, the paper presents a new kind of effective graphite grounding conductor to solve the related problems during the reform or construction process. By discussing the ratio of raw material, the structure designs, the principle of reducing resistance and the installation methods in detail, it proves the effectiveness of this grounding conductor. The formula made up with graphite, high-grade cement, small stones and sands, the graphite grounding conductor can show the characteristics of stable performance, excellent corrosion resistance, non-toxic and pollution-free. In addition, the structure of corrugation or cavity can effectively reduce the ground resistance, and it is quite significant for the safe and reliable operation of the power grid.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 614-615)

Pages:

1348-1351

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yundu Zhang, Xiaoyu Pu (2005) Electric Power Construction. In: Problems existing in ground network of transmission line with renovation measures, vol. 26, no.3, pp.34-35.

Google Scholar

[2] L. Popovic (1998) IEEE Transactions on Power Delivery. In: Practical method for evaluating ground fault current distribution in station, towers and ground wire, vol. 13, no.1, pp.123-128.

DOI: 10.1109/61.660868

Google Scholar

[3] Ruichen Zheng, Jinglu LI (2005) Insulator and Surge Arresters. In: Research on the application of grounding resistance reducer, vol. 6, no.5, pp.43-46.

Google Scholar

[4] Wei LI (2009) Xinjiang Electric Power Technology, Calculation on grounding resistance, vol. 2, pp.68-70.

Google Scholar

[5] Jinliang He, Rong Zeng, Youping Tu (2003) IEEE Transactions on Power Delivery. In: Seasonal influences on safety of substation grounding system, vol. 18, no. 3, pp.788-795, July.

DOI: 10.1109/tpwrd.2003.813895

Google Scholar

[6] (1998) Electrical Power Industry Ministry. In: Grounding of AC Electrical Devices, DL/T621-1997.

Google Scholar

[7] F.P. Dawalibi, D. Mukhedkar (1979) IEEE Transactions on Power Apparatus and System. In: Resistance measurement of large grounding systems, vo1.98, no.6, pp.2348-2354, June.

DOI: 10.1109/tpas.1979.319434

Google Scholar