Investigation and Improvement of Self-Oscillating Electronic Ballast for Local Fluorescent Emergency Light

Article Preview

Abstract:

This paper presents an analysis and improvement of self-oscillation electronic ballast for local emergency light. The improvement circuit has been presented by replacing the original BJTs with MOSFETs as a switching device. Also, 555-timer has been used to drive the MOSFETs instead of the ballast feedback in the original circuit. This electronic ballast start and regulate fluorescent lamps by converting a DC supply to high ignition AC voltage by a rectifier circuit with switching frequency in the range of 20 kHz -1MHz. Operation at high frequency has two advantages; an improved efficiency and elimination of flickering in the lamps. The simulation has been done by using PSIM Simulink software and its results have been compared with experimental results. The results shows that by using MOSFETs as a switching device, the Total Harmonic Distortion (THD) has been reduced and the brightness of lamp tube has been increased greatly.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 614-615)

Pages:

1539-1546

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wu, Y.-C.; Wu, T.-F.; Chen, Y.-K.; , "A compact single-stage converter for emergency lighting applications," Power Electronics Specialists Conference, 2002. pesc 02. 2002 IEEE 33rd Annual , vol.2, no., pp.779-784 vol.2, (2002)

DOI: 10.1109/psec.2002.1022548

Google Scholar

[2] S. H. Hosseini, M. Sabahi and A. Y. Goharrizi, "An improved topology of electronic ballast with wide dimming range, PFC and low switching losses using PWM-controlled soft-switching inverter," Electr. Power Syst. Res., vol. 78, pp.975-984, 6, 2008.

DOI: 10.1016/j.epsr.2007.07.006

Google Scholar

[3] Chin Chang; Chang, J.; Bruning, G.; , "Analysis of the self-oscillating series resonant inverter for electronic ballasts," Industry Applications Conference, 1997. Thirty-Second IAS Annual Meeting, IAS '97., Conference Record of the 1997 IEEE , vol.3, no., pp.2291-2298 vol.3, 5-9 Oct (1997)

DOI: 10.1109/ias.1997.626383

Google Scholar

[4] Takahashi, Y.; Kamatra, M.; Shimizu, K.; , "Efficiency improvement of electronic ballast," Industry Applications Conference, 1997. Thirty-Second IAS Annual Meeting, IAS '97., Conference Record of the 1997 IEEE , vol.3, no., pp.2284-2290 vol.3, 5-9 Oct 199

DOI: 10.1109/ias.1997.626382

Google Scholar

[5] Yim-Shu Lee; Yue-Quan Hu; Kam-Wah Siu; , "Single-switch electronic ballast with near-unity power factor and soft-switching characteristic," Industrial Electronics, IEEE Transactions on , vol.48, no.6, pp.1188-1195, Dec (2001)

DOI: 10.1109/41.969398

Google Scholar

[6] Kazimierczuk, M.K.; , "Class D voltage-switching MOSFET power amplifier," Electric Power Applications, IEE Proceedings B , vol.138, no.6, pp.285-296, Nov (1991)

DOI: 10.1049/ip-b.1991.0035

Google Scholar

[7] Y. R. Yang & C. L. Cheng, "Analysis of Self-Excited Electronic Ballasts Using BJTs/MOSFET as Switching Devises", IEEE Proceeding-Circuits, devises and system, vol. 145, No 2. Pp. 95-104, April 1998.

DOI: 10.1049/ip-cds:19981745

Google Scholar

[8] A. Maamoun, "An Electronic Ballast With Power Factor Correction For Fluorescent Lamps", In Canadian Conference on Electrical and Computer Engineering 2000, Volume 1, 7-10 March 2000, p.385– 389.

DOI: 10.1109/ccece.2000.849735

Google Scholar