Optimum Tilt Angles of Modules on Louvered PV Façade in Changsha, China

Article Preview

Abstract:

This paper aims to evaluate the optimum tilt angle of PV modules on louvered PV façade in Changsha - a city located at middle and low latitude, and representative cloudy climate conditions in Central China. Within these climate conditions, this research discusses the influences of external and internal factors on photoelectric conversion efficiency and shading effect of louvered PV façade. The research result shows that the external and internal design factors of louvered PV façade take opposite effects on the louver tilt angle. Under the influence of external factors, the preferred value interval will be βopt≈Φ and βopt<Φ, whereas under the influence of the internal design factors, the preferred value interval is Φ and above. Taking all factors into consideration, the optimal tilt angle of the PV louver in Changsha is selected as 30°.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 671-674)

Pages:

2135-2140

Citation:

Online since:

March 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] H. Gunerhan, A. Hepbasli. Determination of the optimum tilt angle of solar collectors for building applications. Building and Environment. 42 (2007) 779-783.

DOI: 10.1016/j.buildenv.2005.09.012

Google Scholar

[2] H. Nakamura, T. Yamada, T. Sugiura, K. Sakuta, and K. Kurokawa. Data analysis on solar irradiance and performance characteristics of solar modules with a test facility of various tilted angles and directions. Solar Energy Materials & Solar Cells. 67 (2001).

DOI: 10.1016/s0927-0248(00)00331-7

Google Scholar

[3] F. Jafarkazemi, S.A. Saadabadi and H. Pasdarshahri. The optimum tilt angle for flat-plate solar collectors in Iran. Journal of Renewable and Sustainable Energy. 4(1) (2012) 103-118.

DOI: 10.1063/1.3688024

Google Scholar

[4] R.S. Tang, U. Tong. Optimum tilt angle for solar collectors used in China. Applied Energy. 79 (2004) 239-248.

DOI: 10.1016/j.apenergy.2004.01.003

Google Scholar

[5] S.Y. He, Y.J. Chu S.S. Li, Y.J. Cai. Technology research and application practice on solar photovoltaic curtain wall―take Changsha"zhongjian mansion"as exmple. Architectural Journal. 2 (2009) 102-103.

Google Scholar

[6] J.N. Avaritsiotis. The efficient exploitation of photovoltaic electricity. Solar Cells. 14(3) (1985) 261-279.

DOI: 10.1016/0379-6787(85)90062-6

Google Scholar

[7] ISO 15469/CIE S003: Spatial distribution of daylight-CIE standard overcast sky and clear sky, (1996).

DOI: 10.3403/01451866u

Google Scholar

[8] ISO 15469/CIE S011/E-2003: Spatial distribution of daylight-CIE standard general sky, (2004).

DOI: 10.25039/ds011.2003

Google Scholar