An Innovative Design and Structural Mechanics Analysis of Artificial Hip Joint

Article Preview

Abstract:

Using finite element (FE) method, this work established and comparatively analyzed the basic femoral head model, and six innovative femoral head models with different micropore surface distribution, aiming to explore the most rational surface morphology to have better effect on artificial hip implant. The inboard and outboard femur, the metal handle, and the femoral head’ stress responses were concerned. As the results showed, compared with type A (original femur head, with “smoothed” surface), the other six shaped femur head design all have reduced the maximal stress with different degrees. However, femur model surface type C arranged with 1mm-diametre distributed in three rows of micropore caused the best effect. Within the scope of the study, both micropore size and arranging way influenced the stress distribution at key components of artificial hip joint, especially the effect of micropore size exceeded arranging way of them. Based on the simulation results, it is proposed the whole rigidity of the artificial femoral head with microporous morphology, was reduced to some degree and therefore reducing the stress shielding effect, decreasing the possibility of embedded part being deformed or flexible, which is beneficial to improving life span of the prosthesis.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 694-697)

Pages:

3094-3100

Citation:

Online since:

May 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] M. Soong, H.E. Rubash and W. Macaulay, Dislocation after total hip arthroplasty, J Am Acad Orthop Surg. 12 (2004) 314-321.

DOI: 10.5435/00124635-200409000-00006

Google Scholar

[2] B.T. Hammond, J. Charnley, The sphericity of the femoral head, J Med Biol Eng. 5 (1967) 445-453.

DOI: 10.1007/bf02479138

Google Scholar

[3] F. Menschik, The hip joint as a conchoid shape, J Biomech. 30 (1997) 971-973.

DOI: 10.1016/s0021-9290(97)00051-1

Google Scholar

[4] A.E. Anderson, B.J. Ellis, S.A. Maas and J.A. Weiss, Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip, J Biomech. 43 (2010) 1351-1357.

DOI: 10.1016/j.jbiomech.2010.01.010

Google Scholar

[5] N. Götzen, A.R. Cross, P.G. Ifju and A.J. Rapoff, Understanding stress concentration around a nutrient foramen, J Biomech. 36 (2003) 1511-1521.

DOI: 10.1016/s0021-9290(03)00130-1

Google Scholar

[6] H. Grundei, D.E. LuÜbeck, U.S. Patent 7,771,485. (2010).

Google Scholar

[7] A.E. Anderson, B.J. Ellis, S.A. Maas and J.A. Weiss, Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip, J Biomech. 43 (2010) 1351-1357.

DOI: 10.1016/j.jbiomech.2010.01.010

Google Scholar

[8] O. Kayabasi, F. Erzincanli, Finite element modeling and analysis of a new cemented hip prosthesis, Adv Eng Softw. 37 (2006) 477-483.

DOI: 10.1016/j.advengsoft.2005.09.003

Google Scholar

[9] Y.K. Kanga, H.C. Park, Y. Youma, I.K. Lee, M.H. Ahn and J.C. Ihn, Three dimensional shape reconstruction and finite element analysis of femur before and after the cementless type of total hip replacement, J Biomed Eng. 15 (1993) 497-504.

DOI: 10.1016/0141-5425(93)90065-7

Google Scholar

[10] C.S. Oishi, R.H. Walker and C.W.Jr. Colwell, The femoral component in total hip arthroplasty: six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique, J Bone Joint Surg Am. 76 (1994) 1130-1136.

DOI: 10.2106/00004623-199408000-00003

Google Scholar

[11] X.M. Ding, L.L. Hou, Z.X. Guo, Q. Liu, C.Y. Wang and F. Zhao, Comparative study of stresses on acetabulum after implanted hemisphere and ellipse cup, J Med Biomech. 23 (2008) 465-470.

Google Scholar

[12] A.S. Greenwald, J.J. O'Connor: J Biomech. 4 (1971) 507–512.

Google Scholar

[13] H. Weinans, D.R. Sumner, R. Igloria and R.N. Natarajan, The transmission of load through the human hip joint, J Biomech. 33 (2000) 809–817.

Google Scholar

[14] S. Gross, E.W. Abel, A finite element analysis of hollow stemmed hip prostheses as a means of reducing stress shielding of the femur, J Biomech. 34 (2001) 995–1003.

DOI: 10.1016/s0021-9290(01)00072-0

Google Scholar