Study of the Smart Voltage Control Strategy Based on Three Types of Dates

Article Preview

Abstract:

Based on the characteristics of the three types of data from the system of WAMS (Wide Area Measurement System), SCADA (Supervisory Control And Data Acquisition) and Fault-recorder, this paper present an algorithm to do the voltage or reactive power optimization based on the primal-dual interior point method, and a new method to filter out the noise in state variable based on the standardized residuals. The flow chart proposes a new scheme to use the WAMS real-time data to improve the accuracy of voltage and reactive power control. Keywords: WAMS, voltage and reactive power control, primal-dual interior point method, standardized residuals.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 706-708)

Pages:

1016-1024

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] C.K. Wong , Wu Wei and Han Yingduo, "An Algorithm for Voltage Stability Assessment Based on Synchronized Phasor Measurement",Automation of Electric Power Systems, Vol.2, pp.28-33.

Google Scholar

[2] LiYanan,"Research on Power System Intelligent Reactive Power Optimization and Quasi Real Time Reactive Power/Voltage Control", North China Electric Power University, 2002.

Google Scholar

[3] ChenDeyu, "Study on Intelligent Voltage Control System Based on MAS",Harbin Engineering University, 2010.

Google Scholar

[4] Wang Bin, "Study on Voltage Stability Based on PMU",Yunnan Electric Power, Vol.38, No.3, June.2010, pp.19-20.

Google Scholar

[5] Zhang Xinhua, ShuNaiqiu, Xue Faming, "Voltage and Reactive Power Automation Control System Based on SCADA in Power System", Automation of Electric Power Systems, Vol.27, No.11, June ,2003.

Google Scholar

[6] Nuqui R.F., Phadke A.G., Schulz R.P., Bhatt N., "Fast on-line voltage security monitoring using synchronized phasor measurements and decision trees," Power Engineering Society Winter Meeting, vol.3, pp.1347-1352, 2001.

DOI: 10.1109/pesw.2001.917282

Google Scholar

[7] Pimpa C., Premrudeepreechacharn S., "Voltage control in power system using expert system based on SCADA system," Power Engineering Society Winter Meeting, vol.2, pp.1282-1286, 2002.

DOI: 10.1109/pesw.2002.985222

Google Scholar

[8] Hongga Zhao, "A New State Estimation Model of Utilizing PMU Measurements," Power System Technology, 2006.PowerCon 2006.International Conference, pp.1-5, 22-26 Oct. 2006.

DOI: 10.1109/icpst.2006.321443

Google Scholar

[9] Khodr, H. M., Gomez, J. C.,Barinique, L.,Vivas, J. H.,Paiva, P.,Yusta, J. M.,Urdaneta, A. J. , "A Linear Programming Methodology for the Optimization of Electric Power Generation Schemes," Power Engineering Review, IEEE , vol.22, no.7, p.58, July 2002.

DOI: 10.1109/mper.2002.4312406

Google Scholar

[10] Sun, D.I., Ashley, B., Brewer, B., Hughes, A.,Tinney, W.F., "Optimal Power Flow By Newton Approach," Power Apparatus and Systems, IEEE Transactions on , vol.PAS-103, no.10, pp.2864-2880, Oct. 1984.

DOI: 10.1109/tpas.1984.318284