The Experimental Study of 15CrMo Steel Fatigue Performance

Article Preview

Abstract:

15CrMo steel is widely used in engineering. In order to evaluate the fatigue performance of 15CrMo, axial loading for 15CrMo specimen has applied by high frequency fatigue testing machine under stress ratio R=0.1 at room temperature, the linear S-N relationship has obtained by grouping fatigue test, the fatigue limit has obtained and compared by two different fatigue limit analysis method. The consequences of this test could provide a theoretical support for the use of 15CrMo in engineering and the research of fatigue limit theory.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

214-217

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] ASTM standard E1823-10a, standard terminology relating to fatigue and fracture testing[S]. In: ASTM International, West Conshohocken, PA; 2010. doi:10.1520/ E1823-10A. <www.astm.org>.

Google Scholar

[2] International standard. Metallic materials – fatigue testing – statistical planning and analysis of data. ISO 12107: 2003.

Google Scholar

[3] Zhen-Tong Gao, Jun-Jiang Xiong, Fatigue reliability (Publishing House of BUAA, China, 2000).

Google Scholar

[4] Jian-Ming Zhai, Xiao-yang Li, A methodology to determine a conditional probability density distribution surface from S–N data, International Journal of Fatigue (2012)

DOI: 10.1016/j.ijfatigue.2012.05.008

Google Scholar

[5] Yang You: Experimental Investigation on High Cycle Fatigue Behaviors of MB8 Magnesium Alloy, Journal of materials engineering, China 2010.

Google Scholar

[6] International standard, metallic materials – fatigue testing – axial force controlled method, ISO 1099; 2006.

Google Scholar