Abstract:

In this paper, a variable speed wind turbine model based on doubly-fed induction generator (DFIG) and a section of a practical power grid model to be studied are implemented in DIgSILENT / PowerFactory. The static voltage stability and the transient voltage stability of the regional power grid with high wind power penetration will be studied. Moreover, this paper will focus on the impact of static var compensator (SVC) on both steady state voltage stability and transient voltage stability.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 724-725)

Pages:

659-663

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Datta, R.; Ranganathan, V. T., "A method of tracking the peak power points for a variable speed wind energy conversion system," IEEE Transactions on Energy Conversion, vol.18, no.1, p.163,168, Mar (2003)

DOI: 10.1109/tec.2002.808346

Google Scholar

[2] Yazhou Lei; Mullane, A.; Lightbody, G.; Yacamini, R., "Modeling of the wind turbine with a doubly fed induction generator for grid integration studies," Energy Conversion, IEEE Transactions on , vol.21, no.1, p.257,264, March (2006)

DOI: 10.1109/tec.2005.847958

Google Scholar

[3] Zhongcheng Zhang, Buhan Zhang, Dichen Liu. The Voltage Stability Analysis of Wind Farm Integration to Power System and Improvement Measures[J].Journal of Hubei University of Technology ,2012,27(1):22-25 (In Chinese).

Google Scholar

[4] Yazhou Lei,L. Gordon. An introduction on wind power grid code and dynamic simulation[J].Power System Technology,2005,25(12):27-32(In Chinese).

Google Scholar

[5] Rajakaruna, S.; Bonert, R., "A technique for the steady-state analysis of a self-excited induction generator with variable speed," Energy Conversion, IEEE Transactions on , vol.8, no.4, p.757,761, Dec (1993)

DOI: 10.1109/60.260991

Google Scholar

[6] L. Shi, S. Dai, Y. Ni and L. Yao, , "Transient stability of power systems with high penetration of DFIG based wind farms," in IEEE Power and Energy Society General Meeting, July 2009, p.1–6.

DOI: 10.1109/pes.2009.5276006

Google Scholar

[7] Noroozian, M.; Petersson, N.A.; Thorvaldson, B.; Nilsson, B.A.; Taylor, C.W., "Benefits of SVC and STATCOM for electric utility application," Transmission and Distribution Conference and Exposition, 2003 IEEE PES , vol.3, no., p.1143,1150 vol.3, 7-12 Sept. (2003)

DOI: 10.1109/tdc.2003.1335119