Analysis of Environmental Impact Factors of Natural Draft Cooling Towers in Power Plant

Article Preview

Abstract:

Based on the requirements of Air Clean guidelines (VDI3784 and VDI3945) in German for cooling tower plume rise and dispersion model, a comparative analysis of atmospheric environmental impact of the cooling tower exhaust for different parameters. Parameters includes different source emission parameters and ambient humidity parameters. Then, analysis of the impact factors of plume rising height and the ground concentration according to the emission parameters. The results show that the most influential parameters are temperature and gas flow rate, relatively, the flue gas relative humidity and liquid water content has less influence in the rising height. Therefore, the increase of flue gas flow rate will significantly strengthen the dispersion of pollutants in the air. The flue gas humidity and liquid water have a certain influence on the dispersion of pollutants, but the effect is not so significant. The increase of flue gas humidity and liquid water content is not conducive to the dispersion of pollutants, therefore the surface concentration will only increase slightly.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 726-731)

Pages:

1436-1440

Citation:

Online since:

August 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Keqiang CUI, Wenging HU, Yan WANG, et al. Electric Power. 2006, 39(10): P73–76. (In Chinese).

Google Scholar

[2] Keqiang CUI, Hao LI. Research of Environmental Sciences 2005, 18(1): P27–30. (In Chinese).

Google Scholar

[3] Hua MO, Si-Mei LIU. Electric Power Environmental Protection.2009,25(3):P48-50. (In Chinese).

Google Scholar

[4] Deyong ZENG. Electric Power. 2006, 39(2): P81–85. (In Chinese).

Google Scholar

[5] VDI 3945 Environmental Meteorology Atmospheric Dispersion Models Particle Model. VDI, 2000.

Google Scholar

[6] Yueming LIANG. Study on natural draft cooling towers with flue gas injection. Edtied by North China electric power university, Beijing, 2007. in press.

Google Scholar

[7] Kaihua CHEN, Cunyi SONG, I QiangL. Power System Engineering. 2008, 24(2): P12–14. (In Chinese).

Google Scholar

[8] Yuche LIU, Hongbin YANG, Hongyu WANG, etc. Journal of Meteorology and Environment. 2010, 26(1):P40–44. (In Chinese).

Google Scholar

[9] Feng DING, Yue ZHAO, Xin BO. Safety and Environmental Engineering, 2009, 16(5): P25–29. (In Chinese).

Google Scholar

[10] Shibei LI, Wennan DAI, Yunhui DU. Research of Environmental Sciences 2007, 20(5): P26–30. (In Chinese).

Google Scholar