A Research on Suppression of SSO Based on the Real Time Digital Simulation

Article Preview

Abstract:

According to the first project using SVC to mitigate SSO in China, this paper builds the system model based on real time digtal simulator,and gives an introduction to the sysem model. Under typical operation mode and fault conditions,the performance of SVC is fully validated,it also analysis and comparise the performance of SVC under different operation modes. Simulation results show that the SVC can mitigate the SSO phenomenon.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 732-733)

Pages:

1415-1419

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Liu Shiyu, Xie Xiaorong, Wang Zhonghong. SSR problem in compensated transmission systemof thermal power bases in China. Power SystemTechnology, 2008, 32(1) : 528.

Google Scholar

[2] IEEE SSR Working Group. Countermeasures to subsynchronous resonance problems. IEEE Trans on Power Apparatus and Systems, 1980, 99(5) : 181021818.

DOI: 10.1109/tpas.1980.319771

Google Scholar

[3] Zhang Fan, Xu Zheng. Theory and experiences of SVC for damping subsynchronous resonance. High Voltage Engineering,2007, 33(3) : 26231

Google Scholar

[4] Hammad A E, and EI-Sadek M, "Application of a Thyristor Controlled Var Compensator for Damping Subsynchronous Oscillations in Power Systems", IEEE Transactions on Power Apparatus and System, Vol 103, No.1, pp.198-212, 1984.

DOI: 10.1109/tpas.1984.318608

Google Scholar

[5] L. Wang, and Y. Y. Hsu, "Damping of Subsynchronous Resonance using Excitation Controllers and Static VAR Compensators: A comparative study", IEEE Transaction on Energy Conversion, Vol 3, No I, March 1988.

DOI: 10.1109/60.4192

Google Scholar

[6] Y.Y. Hsu, c.J.Wu, "Design of PID static VAr controllers for the damping of subsynchronous oscillations", IEEE Trans on Energy Conversion, Vol 3, No 2, June 1988.

DOI: 10.1109/60.4720

Google Scholar

[7] Samra N C Abi, Smith R F, Mcdermott T E and Chidester, M.B. , "Analysis of thyristor controlled shunt SSR counter measures," IEEE Trans on PAS, vol.104, pp.584-597, March1985.

DOI: 10.1109/tpas.1985.318976

Google Scholar

[8] Wasynczuk O, "Damping subsynchronous resonance using reactive power control," IEEE Trans on PAS, vol.100, pp.1096-1104, March1981.

DOI: 10.1109/tpas.1981.316576

Google Scholar

[9] Putman T H, and Ramey D G, "Theory of the Modulated Reactance Solution for Subsynchronous Resonance", IEEE Transactions on Power Apparatus and System, Vol WI, No.6, pp.1527-1535, 1982.

DOI: 10.1109/tpas.1982.317201

Google Scholar