Based on the thermo elasticity theory, the stress of femur prosthesis system was analyzed using finite element method. An evaluation for the selection of prosthetic material was presented after discussing the thermo physical property of material which had an effect on the stress of femur prosthesis system. The results indicate that the interface failure is the primary failure form of the femoral prosthesis system and the interface failure is accelerated for the reason of the thermal effect. So the prosthesis with low coefficient of thermal expansion should be selected which can moderate the interface failure in the certain degree.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 750-752)

Pages:

2212-2215

Citation:

Online since:

August 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Bert van Rietbergen, Rik Huiskes. Load transfer and stress shielding of the hydroxyapatite-ABG hip: a study of stem length and proximal fixation. Arthroplasty, 2011, 16(8): 55-63.

DOI: 10.1054/arth.2001.28369

Google Scholar

[2] Gibbons C. E., Davies A. J., Amis A. A. Per prosthetic bone mineral density changes wilt femoral components of differing design philosophy. International Orthopedics, 2001, 25: 89-92.

DOI: 10.1007/s002640100246

Google Scholar

[3] Oquz Kayabasi, Fermi Erzineanli. Finite element modeling and analysis of a new cemented hip prosthesis. Advances in Engineering Software, 2009, 37(2): 477-483.

DOI: 10.1016/j.advengsoft.2005.09.003

Google Scholar

[4] Affatato, Goidoni M, Testoni M. Effect of the Zr02 faction on the weal of ceramic on ceramic hip joint prostheses. Biomaterials, 2011, 22: 717-723.

DOI: 10.1016/s0142-9612(00)00235-0

Google Scholar

[5] Brain W.W., Salvati E.A., Betts F. Metal levels in cemented total hip arthroplasty. Clinical Orthopedics and Related Research, 1992, 276: 66-74.

DOI: 10.1097/00003086-199203000-00010

Google Scholar

[6] Santis R.D. Polymer-based composite hip prostheses. Journal of Inorganic Biochemistry, 2000, 79: 97-102.

DOI: 10.1016/s0162-0134(99)00228-7

Google Scholar

[7] I. Ario and T. Ishii. Optimization lay-out problem in 3-dimensional finite element space. Information-An International Interdisciplinary Journal, 2011, 7(5): 73-78.

Google Scholar

[8] Bi Z.B., Li W.Z., Huang B.H. Analysis and application of the theoretical for thermal stress. China Electric Power Press, 2011, 9.

Google Scholar