The Comparative Analysis of SVC and STATCOM on Subsynchronous Oscillation Mitigation

Article Preview

Abstract:

The methods for subsynchronous oscillation mitigation based on SVC and STATCOM are analyzed in this paper. According to the IEEE first benchmark model, the electrical damping coefficients respectively provided by SVC and STATCOM connected at the generator terminal, as well as positive damping condition, are deduced by complex torque coefficient approach. Correlative factors which influence the two positive dampings are compared. The analysis results indicate that the positive damping provided by SVC is proportional to the size of system voltage. The positive damping provided by STATCOM is not affected by the size of system voltage, which is mostly proportional to the subsynchronous voltage produced itself. The controllers of SVC and STATCOM are designed and the positive dampings separately offered by SVC and STATCOM are optimized by phase compensation with test signal method. The time domain simulation reveals that STATCOM has stronger damping ability than SVC in the case of short circuit fault.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 756-759)

Pages:

245-249

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Gao Benfeng, Xiao Xiangning, Zhao Chengyong, etal. Study on Mitigation of SSO with SVC Based on RTDS. Power System Protection and Control, 2010, 38(23): 6-10+63.

DOI: 10.1109/powercon.2010.5666550

Google Scholar

[2] Liu Yan, Kang Jitao, Li Chenxia, etal. Analysis of Subsynchronous Resonance of Power System with STATCOM. Power System Protection and Control, 2008, 36(20): 38-41.

Google Scholar

[3] Xie Xiaorong, Yang Tingzhi, Jiang Qirong et al. Mechanism Study on the Mitigation of SSR with SVC. Automation of Electric Power Systems, 2008, 32(24): 1-5.

Google Scholar

[4] Zhang Zhiqiang. Study on Mitigatory Measures and Controller Design Based on SVC for Damping SSO. North China Electrical Power University, (2010).

Google Scholar

[5] Johansson, N. Angquist, L. Nee, H. -P. A Comparison of Different Frequency Scanning Methods for Study of Subsynchronous Resonance. IEEE Transactions on Power Systems, 2011, 26(1): 356-363.

DOI: 10.1109/tpwrs.2010.2046345

Google Scholar

[6] IEEE Subsynchronous Resonance Working Group. First Benchmark Model for Computer Simulation of Subsynchronous Resonance. IEEE Trans. on Power Apparatus and Systems, 1977, 96(5): 1565-1672.

DOI: 10.1109/t-pas.1977.32485

Google Scholar