Correlating Visual Grading with NTD Methods for Assessing Timber Condition in Historic Buildings

Article Preview

Abstract:

This study aimed to develop, apply and assess a visual grading system that could evaluate the preservation state of historic buildings structural timbers and correlate it with three NDT methods that are widely used during diagnostic surveys. Assessing timber condition is crucial not only for the structural analysis of buildings, but also for reinsuring that well preserved original material of Cultural Heritage will not be lost. However, assessment based only on NDT results may be biased as it depends on many parameters such as i) the natural variability of wood ii) the type and degree of deterioration iii) the experimental conditions e.t.c. Furthermore, results obtained are not always coinciding and they are often unrelated to the macrosopic condition of timbers. Therefore, this work investigates comparatively a grading system developed based on European with results obtained from ultrasounds application, resistograph profiling and X-ray radiation. The three NDT techniques were tested on samples coming from a post Byzantine mansion in Athens, which presented various types and degrees of decay. For comparison reasons techniques were applied on sound wood of the same species also. Prior to NTD implementation, samples were conditioned in two different RH in order to examine the role of wood moisture on NTD results.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

273-280

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] A.J. Panshin, C. De Zeeuw, Textbook of wood technology: Structure, identification, properties and uses of the commercial woods of the United-states and Canada, McGraw-Hill Book Company, 1980, 722 pp.

Google Scholar

[2] R. A. Zabel, J. J. Morrell, Wood microbiology, decay and its prevention, Academic Press, London, 1992, 476 pp.

Google Scholar

[3] R.A. Eaton, M.D.C. Hale, Wood Decay Pest and Protection, Chapman and Hall, London. 1993, 465 pp.

Google Scholar

[4] B. Ridout, Timber Decay in Buildings: The Conservation Approach to Treatment, English Heritage, Historic Scotland, Spon Press, London and New York, 2004, 232 pp.

Google Scholar

[5] J. M. Branco, M. Piazza, P. J. S Cruz, Structural analysis of two King-post timber trusses: Non- destructive evaluation and load- carrying test, Construction and Building Materials 24 (2010) 371- 383.

DOI: 10.1016/j.conbuildmat.2009.08.025

Google Scholar

[6] V. Bucur, Ultrasonic, hardness and x-ray densitometric analysis of wood, Butterworth, (1985).

Google Scholar

[7] M.R. Grippa, Structural Identification of Ancient timber constructions by NDT, Tesi di dottorato, Università degli Studi di Napoli Federico II, (2000).

DOI: 10.3940/rina.ft.2001.01

Google Scholar

[8] E. Tsakanika-Theohari, H. Mouzakis, A post- byzantine mansion in Athens, The restoration project of the timber structural elements, WCTE, (2010).

Google Scholar

[9] J. D.  Brazier, G. L. Franklin, Identification of hardwoods: A microscope key, Forest Products Research Bulletin No 46, HMSO, London, 1961 96 pp.

Google Scholar

[10] E. W. J. Philips, Identification of softwoods, Forest Products Research Bulletin No 22, HMSO, London, 1979, 56 pp.

Google Scholar

[11] F. H. Schweingruber, Anatomy of European Woods: An Atlas for the Identification of European Trees, Shrubs and Dwarf Shrubs, Verlag Paul Haupt, Bern, 1990, 800 pp.

DOI: 10.2307/4110421

Google Scholar

[12] A. Paraskevopoulou, Anatomical characteristics of wood from Greek conifer species, National Agricultural Research Foundation, Athens, 2003, 50pp (in Greek).

Google Scholar

[13] BS EN 1311: 1997, Round and Sawn Timber- Method of Measurement of Biological Degrade.

Google Scholar

[14] AWPA E7-90, Methods of Evaluating Wood Preservatives by field Tests with Stakes.

Google Scholar

[15] DD 12037: 1996, Wood preservatives- Field Testing for determining the relative protective effectiveness of a wood preservative exposed out of ground contact-Horizontal.

DOI: 10.3403/00867870u

Google Scholar

[16] L. Greenspan, Humidity fixed points of binary saturated aqueous solutions, Journal of research of the National Bureau of Standards, Physics and Chemistry Vol. 81 A, No. 1, (1977).

DOI: 10.6028/jres.081a.011

Google Scholar

[17] J. Creahan, Controlling Relative Humidity with Saturated Calcium Nitrate Solutions, Waac Vol. 13, No. 1, Jan. (1991), pp.17-18.

Google Scholar

[18] F. G. R. de Oliveira, M. Candian, F. F. Lucchette, J. L. Salgon, A. Sales, A technical note on the relationship between ultrasonic velocity and moisture content of Brazilian hardwood (Goupia glabra), Building and Environment 40 (2005) 297- 300.

DOI: 10.1016/j.buildenv.2004.06.002

Google Scholar

[19] B. Marchetti, R. Munaretto, G. M. Revel, E. Primo Tomasini, Non-contact ultrasonic sensor for density measurement and defect detection on wood, 16th WCNDT, Montreal Canada, (2004), 697-709.

Google Scholar

[20] C. J Lin , S. Y Wang, F. C Lin, C. M Chiu, Effect of Moisture Content on the Drill Resistance Value in Taiwania Plantation Wood, Wood and Fiber Science, Vol. 25 (2003) 234-238.

Google Scholar