Structural Behaviour of Precast Lightweight Foamed Concrete Sandwich Panel (PLFP) with Double Shear Truss Connectors under Eccentric Load: Preliminary Result

Article Preview

Abstract:

Recent years in Malaysia, precast concrete sandwich panel gained its popularity in building industries due to its economic advantages, superior thermal and structural efficiency. This paper studied the structural behaviour of precast lightweight foamed concrete sandwich panel (PLFP) with double shear truss connectors under eccentric load. Preliminary results were analysed and studied to obtain the ultimate load carrying capacity, load-deflection profiles and strain distribution across the panel thickness at mid depth. The achieved ultimate load carrying capacity of PLFP due to eccentric load from the experimental work was compared with values calculated from classical formulas (if it is more than 1 comparison) developed by previous researchers. Preliminary results showed that, the use of double shear truss connectors in PLFP was able to improve its ultimate load carrying capacity to sustain eccentric load and achieve certain compositeness reaction in between the wythes.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

414-418

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Engr. M. Haq & Engr. A. Liew, "Light Weight/Low Cost Construction Methods For Developing Countries." CBM-CI International Workshop, Karachi, Pakistan, 2007.

Google Scholar

[2] Suresh, V., "Application of Ferrocement for Cost-Effective Building Construction." Journal of Ferrocement. 34(4): 445-455, 2004.

Google Scholar

[3] Salihuddin Radin Sumadi & Mahyuddin Ramli, "Development of Lightweight Ferrocement Sandwich Panels For Modular Housing and Industrialized Building System." UTM, Research Vote No: 73311, 2008.

Google Scholar

[4] American Concrete Institution, "Building Code Requirements for Reinforced Concrete", ACI 318-89, 1989.

Google Scholar

[5] British Standards, "Structural use of concrete- Part 1: Code of practice for design and construction,", BS 8110-1:(1997)

Google Scholar

[6] N. Mohamad (2010), The Structural Behaviour of PLFP as a Load Bearing Wall. PhD Thesis. Universiti Teknologi Malaysia

Google Scholar

[7] A. Benayoune (2003) Precast Concrete Sandwich Panel As A Building System. Ph.D. Thesis. Universiti Putra Malaysia

Google Scholar