p.1455
p.1459
p.1464
p.1469
p.1473
p.1479
p.1483
p.1489
p.1493
Study on Treatment to Methanol Wastewater by UV/Fenton
Abstract:
In this paper, aqueous methanol (methanol concentration 1000 mg·l-1) degradation was studied by using UV/Fenton, and effect of methanol degradation was evaluated with COD removal rate. When pH was determined, H2O2 dosage, Fe2+ dosage and reaction time were investigated by single factor test, respectively. In the orthogonal experiment, UV/Fenton was used to deal with wastewater of 1000 mg·l-1methanol, the order of the influent factors on COD removal was: H2O2 dosage > reaction time > Fe2+ content. Under the optimal condition (6%H2O250 ml·l-1, Fe2+ 0.9 g·l-1, reaction time 60 min), 95.77% COD removal rate was obtained. In addition, a comparison of UV, Fenton regent and UV/Fenton system indicated that UV and Fe2+ had synergistic effect on catalytic decomposition of H2O2, and reaction time to obtain the highest COD removal was shorted 10 min when UV/Fenton was used.
Info:
Periodical:
Pages:
1473-1478
Citation:
Online since:
September 2013
Authors:
Keywords:
Price:
Сopyright:
© 2013 Trans Tech Publications Ltd. All Rights Reserved
Share:
Citation: