Experiment on Capability of Agriculture Irrigation Water Computation Water Meter

Article Preview

Abstract:

In view of the influence of a certain amount of the sediment in agricultural irrigation water and low temperature to water meter accuracy, experiment of performance and abrasion under the different sediment rate and experiment of the freezing heaving in the different temperature to water meter were developed, the results show, the error rate of water meter is different under different sediment rate, and the error rate become bigger after abrasion 500h under the different sediment rate, and the reading of numerous water meter become smaller. Under the condition of low temperature, the water meter is easy to happen the frost heaving damage phenomenon when the water meter chamber filled with water, and the water meter is generally not heave when water meter chamber not filled with water. The change of water meter accuracy is little after low temperature frost heave.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 807-809)

Pages:

1612-1619

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] ZHAO Jianliang , HU Dixin, Research on verification method of compound water meter [ J]. Journal of Zhejiang University of Technology, 2010, 38 (5): 580-582.

Google Scholar

[2] Wu Yi-chun. The evaluation and application of uncertainty for pressure of accuracy and expression of the water gauge[J], Metrology and Measurement Technique, 2005, 32(11): 36-38.

Google Scholar

[3] Liu Jinsheng. Analysis of the performance parameters of water meter and the normative formulation [J]. Zhejiang Construction, 2010, (3): 69-71.

Google Scholar

[4] Xu Quanhuai. Analysis and discussion of error reason of water meter [J]. Instrument Standardization & Metrology, 2014(5): 41-43.

Google Scholar

[5] Tang min. Evaluation of uncertainty in cold water meter measurement [J]. Metrology & Measurement Technique, 2010, 37(7): 60, 63.

Google Scholar

[6] Li Shijun, Zhang Xiyang, Chen Ling, et al. Design of low-power wireless water meter monitoring system based on GPRS[J], Electronic Measurement Technology, 2010, (7): 108-113.

Google Scholar

[7] Zhang Dianling, Zhi Yifei, Wang Pengjun. The error reason of water flow meter in the calibration period to analyze and countermeasure[J]. Metrology & Measurement Technique, 2006, 33(5): 20-21.

Google Scholar

[8] Yao Ling, Wang Kaituo. The exploration of study methods on impeller type water meter's flow measurement characteristic [J]. Instrumentation Technology, 2010, (8): 10-13.

Google Scholar

[9] Dai Qing. The application of pattern recognition on water meter[D]. Wuhan: Wuhan University of Technology, (2009).

Google Scholar

[10] Yao Ling, Chen Liangyong, Ren Jiang, et al. Research and development of the wide-range WS water meter based on flow measurement characteristics correction technology[J], Instrumentation Technology, 2012, (11): 5-8.

Google Scholar

[11] Xu Quanhuai. Analysis and discussion of error reason of water meter [J]. Instrument Standardization & Metrology, 1998(1): 31-34. ( in Chinese).

Google Scholar

[12] Su Zhe, Zhu Dandan, Wu Junsheng. Freezing influence on the error of water meter [J]. Water Technology, 2009, 3 (12): 45-46, 58.

Google Scholar

[13] Xu Dongyun. Measure management of water meter used by citizen [J]. Metrology & Measurement Technique, 2009, 36(7): 96.

Google Scholar

[14] Huang Rulin. Superficial analysis of relation of dividing line flux and computation nicety degree of water meter[J]. China Metrology, 2010(5): 87.

Google Scholar

[15] Xing Gang. Research on vital techniques of ultrasonic flow measurement [D]. Shandong: Shandong University of Science and Technology, (2007).

Google Scholar