A Control Strategy for the Grid-Side Converter of the Directly-Driven Wind Turbine with PM Synchronous Generator under Unbalanced Grid Voltage

Article Preview

Abstract:

A mathematical model of the full power grid-connecting converter at grid side for permanent magnet synchronous generator (PMSG) under unbalanced grid conditions is built, double-frequency oscillation mechanism on DC voltage is analyzed, and the influence of active power ripple of grid-connecting impedance on dual current control is discussed. To suppress the double-frequency oscillation on DC voltage, and take the grid-connected impedance on active power into account, a dual current control strategy, which based on respectively orientating positive-and negative-sequence voltages,is proposed, and introduced the correction value of active power ripple of grid-connecting impedance to correct reference current of proposed control strategy. Simulation results show that the proposed control strategy can effectively control positive and negative-sequence currents,eliminate the DC voltage double-frequency oscillation,and improve harmonic characteristic of grid-connected current.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 816-817)

Pages:

669-677

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yao Jun, Liao Yong, Zhuang Ka. A Low Voltage Ride-through Control Strategy of Permanent Magnet Direct-driven Wind Turbine Under Grid Faults[J]. Automation of Electric Power Systems, 2009, 33(12): 91-95.

Google Scholar

[2] Morren Johan , de Haan S W H. Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip [J]. IEEE Trans on Energy Conversion, 2005, 20(2): 435-441.

DOI: 10.1109/tec.2005.845526

Google Scholar

[3] Li Jianlin, Hu Shuju, Kong Deguo, et al. Studies on the low voltage ride through capability of fully converted wind turbine with PMSG. Automation of Electric Power Systems, 2008, 32(19): 92-95.

Google Scholar

[4] Conroy J F, Watson R. Low-voltage ride-through of a full converter wind turbine with permanent magnet generator [J]. IET Renew. Power Gen, 2007, 1(3): 182–189.

DOI: 10.1049/iet-rpg:20070033

Google Scholar

[5] Ng C H, Li Ran, Bumby J. Unbalanced grid fault ride through control for a wind turbine inverter [J]. IEEE Trans on Industry Applications, 2008, 44(3): 845-856.

DOI: 10.1109/tia.2008.921429

Google Scholar

[6] Yuan Xufeng, Gao Lu, Wen Jinyu, et al. Unbalanced three-phase control strategy of VSC-HVDC system[J]. Electric Power Automation Equipment, 2008, 44(3): 845-856.

Google Scholar

[7] Geng Qiang, Xia Changliang, Yan Yan, et al. Direct power control in constant switching frequency for PWM rectifier under unbalanced grid voltage conditions[J]. Proceedings of the CSEE, 2010, 30(36): 79-85.

Google Scholar

[8] Zhao Zilong, Wu Weining, Wang Wei. A low voltage ride through technology for direct-drive wind turbines under unbalanced voltage dips[J]. Automation of Electric Power Systems, 2009, 33(21): 87-91.

DOI: 10.1016/j.ijepes.2014.02.035

Google Scholar

[9] Salvador Alepuz, Sergio Busquets-Monge, Josep Bordonau, et al. Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips[J]. IEEE Trans on Industry Electronics, 2009, 5(6): 2162-2173.

DOI: 10.1109/tie.2009.2017102

Google Scholar

[10] Kim K H, Jeung Y C, Lee D C, et al. LVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization [J]. IEEE Trans on Power Electronics, 2012, 27(5): 2376-2384.

DOI: 10.1109/tpel.2011.2171999

Google Scholar

[11] Xiao Lei, Huang Shoudao, Huang Keyuan, et al. DC voltage stability of directly-driven wind turbine with pm synchronous generator during the asymmetrical faults[J]. Transactions of China Electrote-chnical Society, 2010, 25(7): 123-129.

Google Scholar

[12] Chen Yidong, Yang Yulin, Wang Liqiao, et al. Simulation on the control strategy for a full power converter of wind generation under grid fault conditions[J]. Automation of Electric Power Systems, 2011, 35(7): 75-79.

Google Scholar

[13] Hu Jiabing, He Yikang, Wang Hongsheng. Coordinated control of grid and rotor side converters of doubly-fed induction generator under unbalanced network voltage conditions[J]. Proceedings of the CSEE, 2010, 30(9): 97-104.

DOI: 10.1109/supergen.2009.5348139

Google Scholar

[14] Yongsug Suh, Lipo Thomas A. Control scheme in hybrid synchronous stationary frame for PWM AC-DC converter under generalized unbalanced operating conditions [J]. IEEE Trans on Industry Applications, 2006, 42(3): 825-835.

DOI: 10.1109/tia.2006.873673

Google Scholar

[15] Yongsug Suh, Thomas A, Lipo. Modeling and Analysis of Instantaneous Active and Reactive Power for PWM AC/DC Converter Under Generalized Unbalanced Network [J]. IEEE Trans on Power Delivery, 2006, 21(3): 1530-1540.

DOI: 10.1109/tpwrd.2005.860274

Google Scholar

[16] Liao Yong, Zhuang Kai, Yao Jun. A Control Strategy for Grid-Connecting Full Power Converter of Wind Power Generation System Under Unbalanced Grid Voltage [J]. Power System Technology, 2012, 36(1): 72-78.

DOI: 10.1109/tpel.2012.2219884

Google Scholar

[17] Hansen1  AD, Michalke  G. Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults[J]. IET Renewable Power Generation, 2009, 3(3): 333–348.

DOI: 10.1049/iet-rpg.2008.0055

Google Scholar