Particle Size Distribution to the Final Effluent Quality - Based on Turbidity

Article Preview

Abstract:

This paper studies the particle size distribution (PSD) and final effluent quality in the activated sludge process. The PSD of final effluent and mixed liquor were determined, and it was found that the settlement in the process can remove particles between 100μm and 200μm easily, while difficult to remove the particles between 13.5μm to 65μm, which was in the supracolloidal (1-100μm) range and could cause problem at higher flows. The final effluent quality was measured by turbidity. The relationship of PSD-10 with turbidity, was analysed and the formed links were paired. Therefore, the PSD can be linked with final effluent quality and can be expected to use as an index to evaluate the final effluent quality future.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 838-841)

Pages:

1651-1654

Citation:

Online since:

November 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Water Environment Federation: Activated Sludge 2nd Edition. (2002).

Google Scholar

[2] A. Leivine, G. Tchobanoglous, and T. Asano: Characterization of the size distribution of contaminants in wastewater: treatment and reuse implications. Journal WPCF, 1985, 57, (7), 805.

Google Scholar

[3] B. Wilen, P. Balmer: The effect of dissolved oxygen concentration on the structure, size and size distribution of activated sludge flocs. Water Research, 1999, 33, (2), 391.

DOI: 10.1016/s0043-1354(98)00208-5

Google Scholar

[4] D. Snidaro, F. Zartarian, F. Jorand, J. -Y Bottero, J. -C. Bloch, and J. Manem: Characterization of activated sludge flocs structure. Water Science Technology, 1997, 36, (4), 313.

DOI: 10.2166/wst.1997.0146

Google Scholar

[5] D. Hillagardt, and E. Hoffmant, Particle size analysis and sedimentation properties of activated sludge flocs. Water Science Technology. 1997, 36, (4), 167.

DOI: 10.1016/s0273-1223(97)00436-8

Google Scholar

[6] APHA, AWWA, WPCF. Standard Methods for the examination of water and wastewater17th edition. American Public Health Association, Washington, D.C. (1989).

Google Scholar

[7] A. Rawle, Basic principles of particle size analysis. Malvern Instruments. UNDATED.

Google Scholar

[8] WEST JAMES. The consistency of the performance of the rotating biological contactor. MSc thesis, Loughborough University. (2001).

Google Scholar