Renewal of Panel Residential Houses from the Point of View of Energy Criterion

Article Preview

Abstract:

A complex renewal of residential houses is a renewal of flats and common areas of the house so that they meet effective regulations and standards. Most of the residential houses in Slovakia built during last sixty years fall into the category of panel systems. An important criterion for determination of the extent of renewal of panel residential houses is required specific energy need for heating (energy criterion) and proving of precondition of satisfaction of energy economy of a building (criterion of minimum requirement on energy economy of buildings). In connection with the effect of new standard STN 73 0540:2012, the requirements for building constructions and buildings changed. Therefore, the residential houses of panel systems were evaluated in this paper from the point of view of the energy criterion both in original state and after the renewal by adding thermal insulation on walls, roof and replacement of windows.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

71-74

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] STN EN ISO 13790 Energy performance of buildings, Calculation of energy use for space heating and cooling (ISO 13790: 2008), SÚTN 2009. (in slovak).

DOI: 10.1016/j.enbuild.2006.06.007

Google Scholar

[2] STN 73 0540-2 Thermal protection of buildings, Thermal performance of buildings and components, Part 2: Functional requirements, SÚTN 2012. (in slovak).

Google Scholar

[3] R. Menďan, B. Vavrovič, Renewal of Prefabricated Residential Buildings, Complex Solution of Structural, Technological, Hygienic and Energy Problems, 5. Thermal Assessment of Panel Residential Buildings and Elimination of Hygienic Defects, Bratislava: STU in Bratislava, 2008. 219 pp., ISBN 978-80-227-2872-0. (in slovak).

DOI: 10.4028/www.scientific.net/amr.855.89

Google Scholar

[4] W. Heindl et al, Wärmebrücken, Springer-Verlag, Wien, 1987, 288 s, ISBN-13: 978-3211820247.

Google Scholar

[5] E. Cziesielski, I. Kohl, Katalog Instandsetzung und Modernisierung von vorgefertigten Außenwänden, Sanierungshandbuch Plattenbau, Fraunhofer Irb Verlag, 1994, ISBN-13: 978-381674.

Google Scholar

[6] Program TERMO´13 - A modul – Program for complex thermal-technical evaluation of building constructions (author: Ing. R. Menďan, PhD. ) (in slovak).

Google Scholar

[7] Program TERMO´13 - B modul – Program for calculation and evaluation of energy need for heating of a building (author: Ing. R. Menďan, PhD. (in slovak).

Google Scholar

[8] STN 73 0540-3 Thermal protection of buildings, Thermal performance of buildings and components, Part 3: Properties of environments and building products, SÚTN 2012. (in slovak).

Google Scholar

[9] L. Vargic, D. Kapičák, A. Kosíková, Z. Barnová, A. Fardová, Complex Evaluation of Panel Residential Buildings from Hygienic and Energy Point of View, ŠVK work, Supervisors: Ing. R. Menďan, PhD., Ing. V. Gašparovičová, PhD., 2013. (in slovak).

Google Scholar