Research on Tensile Bearing Capacity of Self-Drilling Screw Joints for Thick Faced Roof Sandwich Panels

Article Preview

Abstract:

To find out the connection of screw joints and base materials or the metal crest surface at the head of screw which is destroyed first, the tensile bearing capacity of joints between self-drilling screws (SDS) and the base materials were tested first. With two types of SDS joints furnished with C-saddle washers (C-SW) and M-saddle washers (M-SW) respectively, test and analysis on the tensile bearing capacity of SDS joints were undertaken. Corresponding finite element (FE) models were analyzed by ANSYS/LS-DYNA software. Based on mechanical analysis, a new theoretically computational formula for tensile bearing capacity of SDS joints is proposed.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

122-126

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Wei-Wen Yu: Cold-formed Steel Design ( 3rd Edition) (John Wiley & Sons, Inc. , New York 2000).

Google Scholar

[2] American Iron and Steel Institute: Specification for the Design of Cold-Formed Steel Structural Members(1996).

Google Scholar

[3] QIN Peicheng: Theoretical and Experimental Study on the Bending Behavior of Metal Faced Sandwich Panel( PhD thesis, Harbin Institute of Technology, Harbin 2011).

Google Scholar

[4] Chen Ji: Stability of Steel Structures Theory and Design (5th Edition) (Science Press, Beijing 2011).

Google Scholar