Experimental Research on the Effect of Cross-Wind to Wet-Cooling Tower Performance

Article Preview

Abstract:

Environmental cross-wind has a influence on cooling capacity of wet cooling tower to a great extent in power plant.The variation of circulating-water temperature difference (Δt) and cooling coefficient of efficiency(η) with cross-wind velocity, circulating water inlet temperature and flow rate, are shown under cross-wind conditions, compared with cases without wind. By using experimental platform of cooling water system based on 300MW thermal power unit,it is found that with cross-wind velocity increasing,cooling temperature difference and cooling efficiency decrease first then increase at the knee point when the velocity value is 0.8m/s. In addition, the correlation betweenΔt ,η and parameters,such as circulating-water inlet temperature and flow rate, is derived for cases with windless conditions.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 860-863)

Pages:

1412-1415

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] LI Xiuyun , YAN Junjie: Proceedings ofthe CSEE Vol. 21(2001), p.94.

Google Scholar

[2] J. Smrekar, J. Oman: Energy Conversion and ManagementVol47(2006), p.1086.

Google Scholar

[3] Z. Zhai, S. Fu: Applied Thermal EngineeringVol26(2006), p.1008.

Google Scholar

[4] J.C. Kloppers, D.G. Kröger: International Journal of Heat and Mass Transfer Vol 48(2005), p.765.

Google Scholar

[5] Johannes C. Kloppers, DetlevG. Kröger: International Journal of ThermalSciences Vol44(2005), p.879.

Google Scholar

[6] S.P. Fisenko, A. a. Brin and A.I. Petruchik. International Journal of Heat and Mass TransferVol47(2004), p.165.

Google Scholar

[7] S.P. Fisenko, A.I. Petruchik et al: InternationalJournal of Heat and Mass TransferVol 45(2002), p.4683.

Google Scholar

[8] Y. Caytan: Fifth IAHR Cooling Tower Workshop, (1980).

Google Scholar

[9] J.G. Ribier: Fifth IAHRCooling Tower Workshop, (1980).

Google Scholar

[10] C. Bourillot, J. Grange, J.M. Lecoeuvre. FifthIAHR Cooling Tower Workshop, (1980).

Google Scholar

[11] H. Henning: Fifth IAHR Cooling Tower Workshop, (1980).

Google Scholar

[12] A.F. DupreezandD.G. Krer: 8th Cooling Tower and Spraying pondSymposium, (1992).

Google Scholar

[13] Q. Wei et al: Journalof Wind Engineering and Industrial Aerodynamics Vol54/55(1995), p.633.

Google Scholar

[14] Ming Gao, F. ZH. Sun, Y.T. Shi, Kai Wang, Y.B. Zhao: International Journal of Thermal Sciences Vol47(2008), p.935.

Google Scholar