Application of FTA and Improved FAHP in Power Transformer Risk Assessment

Article Preview

Abstract:

For fast and accurately assessing the risk of the transformer failure and getting the reliability of transformer components, it is proposed a new method based on Fault Tree Analysis (FTA) and Improved Fuzzy Analytic Hierarchy Process (IFAHP) in this paper. Firstly power transformer fault tree is established accordingly to make the complex transformer faults system subdivide into various kinds of basic types directly; Secondly, the IFAHP is designed to analyze the fault tree, so the complex system of transformer can be quantitatively described and the fuzzy judgment matrix can be established; Finally, the fuzzy consistent qualification is changed into a mathematical programming problem and Genetic Algorithms (GA) is adopted to get the solution so as to obtain the reliability of transformer components. In addition, the application result shows the effectiveness of the method above.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 860-863)

Pages:

2157-2160

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Fischer M., Tenbohlen S., Schafer M. and Haug R.: IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 18 (2011), pp.1789-1798.

DOI: 10.1109/tdei.2011.6032851

Google Scholar

[2] Na Liu, Guodong Liang, Liufang Wang, Wei Li, Wensheng Gao and Kexiong Tan: High Voltage Engineering (in Chinese), Vol. 29 (2003), p.3.

DOI: 10.1109/icpadm.2003.1218455

Google Scholar

[3] Peng Sun and Shaohui Chen: Risk Matrix Model of Transformer Based on Failure Rate and Importance of Equipment (Forum on Electric Power Tech, Yunnan, China, 2011).

Google Scholar

[4] S. S. Agarwal and M. L. Kansal: Fuzzy fault tree analysis of a power transformer (International Conference on Quality, Reliability, Risk, Maintenance, and Safety Engineering, Sichuan, China, 2012).

DOI: 10.1109/icqr2mse.2012.6246393

Google Scholar

[5] Cuifen Bai, Wensheng Gao and Dengwei Ding: high voltage Technology (in Chinese), Vol. 36 (2010), pp.869-872.

Google Scholar

[6] Youyuan Wang, Jingjing Zhou, Weigen Chen, Lin Du, Rengang Chen, Liang Zhang and Weiguang Song: Study of an Assessment Method for the Reliability of Tap-changers in Power Transformer Based on Fault-Tree Analysis (International Conference on High Voltage Engineering and Application, Chongqing, China, 2008).

DOI: 10.1109/ichve.2008.4774008

Google Scholar

[7] H. Boudali, P. Crouzen and M. Stoelinga: IEEE Transactions on Dependable and Secure Computing, Vol. 7 (2010), pp.128-143.

DOI: 10.1109/tdsc.2009.45

Google Scholar

[8] Yucheng Dong, Weichiang Hong, Yingfeng Xu, and Shui Yu: IEEE Transactions on Fuzzy Systems,  Vol. 19 (2011), p.13.

Google Scholar