Study on Switch-On and Switch-Off Time of On-Line Monitoring for the Vacuum Circuit Breaker in Traction Substation

Article Preview

Abstract:

This paper studies the method of determining switch-on and switch-off time of on-line monitoring system for vacuum circuit breakers in traction substation based on engineering project. In switch-on and switch-off process, the on-line monitoring system gets displacement signal of moving contact through the guyed displacement sensor, and gets vibration signal through the piezoelectric acceleration sensor, then the signal monitored is sent to the industrial personal computer through the data acquisition unit taking DSP as the core and the communication network. After comprehensive analysis by the backstage management software in the computer, switch-on and switch-off time can be determined.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 860-863)

Pages:

2218-2222

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] (In Chinese)Yongpeng Meng, Shenli Jia, Mingzhe Rong, Application of Short-Time Energy Analysis in Condition Monitoring of Circuit Breaker. JOURNAL OF XI'AN JIAOTONG UNIVERSITY, 2004, 38(12): 1301-1305.

DOI: 10.1109/icpst.2002.1067807

Google Scholar

[2] (In Chinese)Wu Yang, Mingzhe Rong, Degui Chen, et al. Electromagnetic compatibility design for photovoltaic pumping systems. Advanced Technology of Electrical Engineering and Energy, 2002, 21(3): 57-60.

Google Scholar

[3] (In Chinese)Guoheng Xu, Jierong Zhang, Jiali Qian, et al. Theories and Application of High-voltage Breakers. Beijing: Tsinghua University Press, (2000).

Google Scholar

[4] (In Chinese)Limin Zhu, Binglin Zhong, Minping Jia, Short-time Processing of Vibration Signal and Its Application in Machine Fault Diagnosis. Journal of Vibration Engineering, 2000, 13(3): 400-405.

Google Scholar

[5] (In Chinese)Yongpeng Meng, Shenli Jia, Mingzhe Rong, On-line Monitoring Method for Mechanical Characteristics of Vacuum Circuit Breakers . High Voltage Apparatus, 2006 , 42(1): 31-34.

DOI: 10.1109/deiv.2004.1422616

Google Scholar

[6] (In Chinese)Zhensheng Wu, Wei Wang, Xuechang Yang, et al, On-line monitoring of operation time for SF6 high-voltage circuit breakers based on wavelet algorithm. ELECTRIC POWER , 2006, 39(6): 26-29.

DOI: 10.1109/icems.2005.202948

Google Scholar