Safety Evacuation at Metro Transit Station in Shenyang under Fire

Article Preview

Abstract:

It's necessary to pay much attention to the public safety issues of subway because of the rapid development of urban subway. Safety evacuation under different fire scenarios were simulated by using SIMULEX 2.0 at Metro transit station (Youth Street station) in Shenyang combined the actual structural characteristic. The results show that the evacuation capacity of Metro Line 1 is smaller than Metro Line 2; the staircase to the station hall of Metro Line 1 would be the bottleneck of the entire evacuation process; different paths have a great influence on the evacuation time; the staircase width from the platform to the station hall is the bottleneck in the evacuation procedure.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 864-867)

Pages:

849-852

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] K. Fridolf, D. Nilsson and H. Frantzich. Fire Evacuation in Underground Transportation Systems: A Review of Accidents and Empirical Research, Fire Technology, Vol. 49(2013), pp.451-475.

DOI: 10.1007/s10694-011-0217-x

Google Scholar

[2] Hiroyuki Kadokura, Ai Sekizawa and Wataru Takahashi. Study on availability and issues of evacuation using stopped escalators in a subway station, Fire and Materials, 36(5/6), (2012).

DOI: 10.1002/fam.1097

Google Scholar

[3] R. Könnecke and V. Schneider. Evacuation from underground railway stations — Available and required safe egress time for different station types and general evaluation criteria, Pedestrian and Evacuation Dynamics 2005, (2007), pp.363-368.

DOI: 10.1007/978-3-540-47064-9_34

Google Scholar

[4] Moriyama, Shuji, Hasemi, Yuji , Nam, Don-Gun, Tanaka, Satoshi , Okazawa and NaomiDing, Wenting. Smoke movement characteristics and fire safety in subway stations, Fire Safety Science - Proceedings of the 8th International Symposium, (2005).

DOI: 10.3801/iafss.fss.8-1461

Google Scholar

[5] Huijun Zhu. The characteristics of the urban subway fire, accident analysis and prevention measures, Security Technology and Management, (2011), pp.37-40(In Chinese).

Google Scholar

[6] Zhongri Hu. The domestic and international developing trends of Safety evacuation study, Fire Science and Technology, (2001), pp.7-21(In Chinese).

Google Scholar

[7] Xinli Zhou, Rui Chen and Li Zhang. Simulation Analysis of Passengers' Evacuation during Subway Fire Accident, Urban Mass Transit, (2009), pp.30-39(In Chinese).

Google Scholar

[8] Huijun Liang and Wenbin Xu. Performance Analysis on Evacuation in Subway Fire, Journal of Shenyang Jianzhu University (Natural Science), Vol. 28 (2012), pp.702-709(In Chinese).

Google Scholar

[9] Code for metro design》(GB50517-2003), Beijing , China Planning Press(In Chinese).

Google Scholar

[10] Xianchao Wu, Dan Xie and Long Li . An analysis on the occupants evacuation time computation of the subway platform, Journal of Shenyang Aerospace University, Vol. 29 (2012), pp.68-73(In Chinese).

Google Scholar