Dehumidification is considered as a key feature of HVAC systems for thermal comfort. Malaysia is located in the South East Asia region which has a sufficiently high temperature and humidity of approximately 80% RH. This requires a process which can reduce moisture in the air. Desiccant wheel is used to provide dehumidification. Desiccant wheel with model no. 770 WSG produced by NOVELAIRE having operating system 1:1 and maximum flow rate of 1500 cfm has been theoretically and experimentally analyzed for its performance. The results show good matching between theoretical and experimental results in term of sensible and latent effectiveness of dehumidification process as well as regeneration process. This desiccant wheel is capable of condensing water at 0.05kgH2O/s and providing 3.3639 kW load reduction. With this significant load reduction, the component integrated in solar hybrid desiccant air-conditioning system can perform comfort cooling to area with high latent load such as hall, hyper market and commercial building.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 875-877)

Pages:

1888-1894

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Meckler M. Desiccant outdoor air pre-conditioners maximize heat recovery ventilation potentials. ASHRAE Trans Symp 1995. SD-95-9-4.

Google Scholar

[2] Fang I, Clausen G, Fanger PO. Impact of temperature and humidity on the perception of indoor air quality. Indoor air 1998; 8(2): 80-90.

DOI: 10.1111/j.1600-0668.1998.t01-2-00003.x

Google Scholar

[3] Daou, K., Wang, RZ., Xia, Z.Z. Desiccant cooling air conditioning: a review. Renewable Sustainable Energy Rev 2006. 10, 55-77.

DOI: 10.1016/j.rser.2004.09.010

Google Scholar

[4] Jain, S., Dhar, P.L., Kaushik, S.C. Evaluation of solid-desiccant-based evaporative cooling cycles for typical hot and humid climates. Int. J. Refrigeration 1995. 18(5)287-296.

DOI: 10.1016/0140-7007(95)00016-5

Google Scholar

[5] Dhar, P.L., Singh, S.K. Studies on solid desiccant based hybrid air-conditioning systems. Appl. Therm. Eng 2001. 21, 119-134.

DOI: 10.1016/s1359-4311(00)00035-1

Google Scholar

[6] Liu, W., Lian, Z., Radermacher, R., Yao, Y. Energy consumption analysis on a dedicated outdoor air system with rotary desiccant wheel. Energy 2007. 32, 1749-1760.

DOI: 10.1016/j.energy.2006.11.012

Google Scholar

[7] Hao, X., Zhang, G., Chen, Y., Zou, S., Moschandreas, D.J. A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification. Build. Environ 2007, 42, 3298-3308.

DOI: 10.1016/j.buildenv.2006.08.020

Google Scholar

[8] Niu, J.L., Zhang, L.Z., Zuo, H.G. Energy savings potential of chilled ceiling combined with desiccant cooling in hot and humid climates. Energy Build 2002. 34, 487-495.

DOI: 10.1016/s0378-7788(01)00132-3

Google Scholar

[9] Giovanni A. Longo, Andrea Gasparella. Solar Energy 83 (2009), pp.511-521.

Google Scholar

[10] M. Ali Mandegari, H. Pahlavanzadeh. Energy 34 (2009), p.797–803.

Google Scholar