High Voltage Circuit Breaker on-Line Monitoring System

Article Preview

Abstract:

The high voltage circuit breaker is an important power system equipment. The reliability of its running relationship with the safe operation of the entire power system. High voltage circuit breaker on-line monitoring system enables real-time monitoring of various parameters during the operation in which the circuit breaker, and the use of communication to achieve data transfer bus information. Through monitoring points, closing coil current signals to constitute the core of C8051F online monitoring unit via RS-485 serial bus will monitor information is uploaded to the master computer.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

668-671

Citation:

Online since:

February 2014

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Li Chunsheng. Comparison of the reliability of high voltage circuit breaker electrical and mechanical linkage. Industrial Technology, 2006, (7).

Google Scholar

[2] Xu Jianyuan, Lang Fucheng. Current situation and development trend of mechanical characteristics of high voltage circuit breaker online monitoring technology. Huatong Technology, 2005, (2).

Google Scholar

[3] Hu Xiaoguang, Sun Laijun. SF6 Study on the method of circuit breaker on-line insulation monitoring. Electric power automation Equipment, 2006, 26(4).

Google Scholar

[4] Wang Yang, Pu Zailin, Wang Xuemei, etc. Several calculation methods of circuit breaker life on-line monitoring. Journal of Shenyang Agricultural Uinversity, 2005, 36(1).

Google Scholar

[5] Li Bin. Value and its online monitoring technology conversion, the electrical life of circuit breakers limit. High voltage electrical apparatus, 2005, 41(6).

Google Scholar

[6] E. Zaima, S. Okage, Application of dynamic are equations to arc extinctions in SF6 circuit breaker. IEEE Trans. Power Deliv. 8 (3) (1993).

Google Scholar

[7] Bretthauer, G., Handschin, E., Neumann, U., Weber, Th., and Wellssow,W. H.: New approaches for maintenance management for grid facilities, CIGRE Paris, 1998, Paper No. 23/37/39-01.

Google Scholar

[8] Zhang, X.; Pietsch, G.; Gockenbach, E.: Investigation of the thermal transfer coefficient by the energy balance of fault arcs in electrical installations. IEEE Trans. Power Deliv. 21(1), 425–431 (2006).

DOI: 10.1109/tpwrd.2005.852274

Google Scholar

[9] Ziani, A.; Moulai, H.: Extinction properties of electric arcs in high voltage circuit breakers. J. Phys. D Appl. Phys. 42(10), 105205 (2009).

DOI: 10.1088/0022-3727/42/10/105205

Google Scholar