Evaluation of Thermal Environment and Indoor Air Quality in University Libraries in Vienna

Article Preview

Abstract:

This contribution presents the results of an indoor environmental study of university libraries in Vienna. Indoor climatic parameters (air temperature, relative humidity, and CO2 levels) in the main spaces of four different library buildings (two historic buildings from the 19th century, two buildings from the late 20th century) were monitored over a period of ten months. Furthermore, to obtain a general impression of the quality of the visual environment in these buildings, illuminance levels at selected locations were measured. The measured data was analyzed and enriched with additional calculated indicators (e.g., PMV/PPD). To put the monitored data in the proper context, recorded outdoor climate data was also taken into consideration. The findings point to a certain overheating risk during the summer period as well as increased CO2 levels during the winter period.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

315-320

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] ÖNORM EN 12464-1: 2011 07 01. Light and lighting - Lighting of work places - Part 1: Indoor work places.

DOI: 10.3403/02729981u

Google Scholar

[2] AStv 1998, ArbeitnehmerInnenschutzgesetz (accessed September 2013) http: /www. ris. bka. gv. at/GeltendeFassung. wxe?Abfrage=Bundesnormen&Gesetzesnummer=10008910.

Google Scholar

[3] ASchG 1994, Arbeitsstättenverordnung (accessed September 2013)http: /www. ris. bka. gv. at/ GeltendeFassung. wxe?Abfrage=Bundesnormen&Gesetzesnummer=10009098.

Google Scholar

[4] E. Righi, G. Aggazzotti, G. Fantuzzi, V. Ciccarese, G. and Predieri 2001. Air quality and well-being perception in subjects attending university libraries in Modena (Italy). Modena, Italy.

DOI: 10.1016/s0048-9697(01)00960-3

Google Scholar

[5] J.Y. Suk, M. Schiler, Thermal comfort performance tests of USC' three libraries using dataloggers, School of Architecture University of Southern California, Los Angeles (2007).

Google Scholar

[6] ÖNORM EN ISO 7730: 2006 05 01. Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria (ISO 7730: 2005).

DOI: 10.3403/30046382

Google Scholar

[7] H. -P. Hutter,H. Moshhammer, P. Wallner,P. Tappler, F. Twrdik, E. Gangllberger, and S. Geissler, 2005. Forschungsvorhaben F1469, Auswirkungen energiesparender Massnahmen im Wohnbau auf die Innenraumluftqualitaet und Gesundheit. Endbericht. Vienna, Austria.

Google Scholar

[8] M.J. von Pettenkofer, Handbuch der Hygiene und der Gewerbekrankheiten, 1882-94.

Google Scholar

[9] ÖNORM EN 13779: 2008 01 01. Ventilation for non-residential buildings - Performance requirements for ventilation and room-conditioning systems.

DOI: 10.3403/03294485

Google Scholar